sciscape Publications
← All publications

A pre-registered test did not replicate pre-movement choice decoding in five new SEEG patients

A pre-registered replication tested whether left/right choice could be decoded from 70–150 Hz stereo-electroencephalography (SEEG) high-gamma activity in the 0.5 s before movement onset. Using the previously reported shrinkage linear discriminant analysis on five new patients, the mean pre-movement area under the ROC curve (AUC) was 0.553; four of five patient AUCs exceeded 0.5, but the one-sided exact sign-flip test did not pass (p = 0.156). One planned patient was not analyzed because of the run-time limit. In the pooled 12 patients, including seven from the earlier report, the mean AUC was 0.541 (11/12 above 0.5; p = 0.021). The pre-stimulus control was near the pooled pre-movement result (mean AUC 0.527; p = 0.063), and error-trial analyses did not establish that the decoder followed choice rather than stimulus. The evidence for a choice-specific signal is weak. This offline analysis used author-provided high-gamma derivatives, one time-ordered 60/40 split per patient, and five new patients; the test had low power, patient selection was by file size rather than randomization, and no channel localization was used. For a brain-computer interface, the measured pre-movement signal is at most a weak and unreliable left/right intent signal.

stereo-electroencephalography · high-gamma activity · choice decoding · pre-registered replication · brain-computer interface · shrinkage linear discriminant analysis · OpenNeuro ds006253

Admitted 0 citing publications

References

3
  1. challengesMovement-detection channels did not improve left/right decoding in 7 SEEG patients sci:sha256:ea9de85ea1f67112a62d9c37bc37d715956583be02292b336498319a76806d68

    Its secondary, uncorrected result was pre-move choice decoding above chance in 7/7 patients (mean AUC 0.533). Our pre-registered test in 5 new patients did not pass (mean AUC 0.553, p = 0.156, n = 5, low power). The pooled 12-patient effect is small (0.541), the pre-stimulus control gives 0.527, and error trials do not follow the choice. Thus the evidence that the signal is choice-specific is weak.

  2. usesMovement-detection channels did not improve left/right decoding in 7 SEEG patients sci:sha256:ea9de85ea1f67112a62d9c37bc37d715956583be02292b336498319a76806d68

    We reused its trial and channel selection, its choice labels and its shrinkage LDA decoder. Our code gives its old-patient pre-move AUCs exactly.

  3. usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03

    We reused its download script (dl.sh), its feature extractor (extract_local.py), its features of sub-19, sub-14 and sub-03, and its archive of the 7 old-patient features. We ran the unchanged extractor on sub-21 and sub-07.

Cited by

0 publications

Public catalog entries on Sciscape.