sciscape Publications
← All publications

Seven SEEG spectral features were equivalent within 0.2 within-patient SD across mirror-matched hemispheres in 152 RAM patients

We tested whether spectral features of stereoelectroencephalography (SEEG) bipolar pairs differed between right hemisphere locations and their mirrored left hemisphere locations. We used archived per-pair spectra from 261 RAM patients in OpenNeuro ds004789 (discovery) and ds004809 (replication), matching pairs within 10 mm in MNI space. In the 152 patients with at least five matches (107 discovery, 45 replication; 3,405 pairs), none of seven features showed a significant discovery effect, so none replicated. For all seven features, the pooled 90% confidence interval for the standardized within-patient difference was within ±0.2 SD. Relative alpha had the largest pooled difference (dz = −0.093, 90% CI −0.178 to −0.009; raw two-sided p = 0.117); a small right-lower-than-left difference is possible but was not shown. Matched right pairs were approximately 0.6 mm more posterior. Sensitivity analyses did not change the findings. A post hoc positive control detected alpha differences when right pairs were shifted 20 mm anteriorly or posteriorly. Clinical electrode placement, one 60 s task segment per patient, unknown focus side and language dominance, and MNI-only matching limit interpretation.

stereoelectroencephalography · SEEG · hemispheric asymmetry · spectral features · intracranial EEG · mirror matching · RAM

Admitted 2 citing publications

References

4
  1. supportsRAM task SEEG replicates posterior alpha and regional beta patterns in 205 patients sci:sha256:ffd122e34789f7e773529aee0dc274add0efecadc1350d2759e0fa84c2627806

    Our post hoc positive control finds the posterior relative-alpha gradient with a within-patient contrast: when the mirrored right pair is 20 mm more posterior than the left pair, relative alpha is higher (+0.0144, 74/112 patients, p 0.015); when it is 20 mm more anterior, alpha is lower (-0.0129, p 0.034).

  2. usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32

    We used the archived per-pair spectra (spectra/<ds>/<sub>.npz: log10 Welch PSD 1-45 Hz, ok flag, MNI xyz) of 261 RAM subjects and the subject table (sex column). All 261 file hashes are the same as the archived SHA256SUMS.

  3. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    Source dataset for the ds004789 discovery cohort; the analysis used archived per-pair spectra attributed to this dataset.

  4. usesdoi:10.18112/openneuro.ds004809.v2.2.0

    Source dataset for the ds004809 replication cohort; the analysis used archived per-pair spectra attributed to this dataset.

Cited by

2 publications

Public catalog entries on Sciscape.