Bands of 5 Hz set from session 1 showed no clear alpha reactivity ICC gain over fixed 8-13 Hz bands over one month in 60 ds004148 adults
We tested whether a frequency band set for each person improved repeat EEG measurements in 60 adults from OpenNeuro ds004148 version 1.0.1. For each person, the largest closed-eye power density from 8 to 13 Hz in session 1 set the center of a 5 Hz band. We then tested sessions 2 and 3, about one month apart. Neither test session supplied data for band selection. The outcome was the closed-eye to open-eye power ratio in decibels. The comparison used a fixed 8-13 Hz band. The primary absolute-agreement ICC was 0.4347 for the person band and 0.4335 for the fixed band. The paired ICC change was 0.0012, with a 95% person-bootstrap interval of -0.0277 to 0.0360 from 10,000 draws. Six planned method checks also gave no clear gain. This does not prove equal performance. The evidence applies to the tested band maximum rule, source processing, and young adult sample. The package preserves all 360 input spectra, source hashes, source and analysis code, tables, random draws, and reproduction instructions. Independent numerical checks passed. Two fresh full EEG record checks rebuilt the archived arrays exactly.
electroencephalography · alpha reactivity · test-retest reliability · intraclass correlation · individualized frequency bands · bootstrap uncertainty
References
5- usesWith the tested method, 60-second closed-eye segments met the 0.10 ICC loss limit for one-month 8-13 Hz maximum frequency in 60 ds004148 adults sci:sha256:b77cbca486bed64f6f7aebd65afc54b61a6beed5dc0060889fb72841cd5b5170
The published maximum-frequency agreement result supplied context for testing bands set per person. Its result files were not used in this analysis, and it was not treated as a new sample.
- usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape
The archived spectra, source extraction code, quality flags, headers, and source hashes supplied the input for the session 1 band rule and the test on sessions 2 and 3. A separate check reproduced the parent fixed-band ICC.
- usesdoi:10.18112/openneuro.ds004148.v1.0.1
Version 1.0.1 is the recorded source dataset for the 60 participants and EEG sessions.
- supportsdoi:10.1038/s41597-022-01607-9
The dataset paper supplies source-study and acquisition details cited in the publication.
- doi:10.1037/1082-989X.1.1.30
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.