Early threshold calibration reduced false alarms and missed most key responses in continuous SEEG replay from eight patients
We tested a fixed SEEG decoder as a continuous response trigger. We used all eight patients in OpenNeuro ds004473, version 1.0.2. For each patient, the first 40% of valid trials trained the model. The next 20 trials set a threshold with at most one observed false alarm per non-target minute. The final 40 trials tested the fixed model and threshold. The test had 320 responses and 38.18 minutes of replay. Mean event-window balanced accuracy was 72.0%. The zero threshold gave 38.89 false alarms per minute and detected 45.6% of responses before the recorded key time. The calibrated threshold gave 1.66 false alarms per minute and detected 9.7%. Its later rate exceeded one per minute in seven of eight patients. Descriptive 95% patient bootstrap intervals were 1.09 to 2.16 for the calibrated rate and 4.4% to 16.6% for detection. A rule that also accepted short post-response alarms detected 21.9% after calibration. The package preserves four figures, every continuous score, alarm times, model weights, source hashes, raw fixtures, code, and repeat instructions. This is an offline test in one task recording per patient. The short calibration period cannot certify rare false alarms. The labels are recorded key times. The test does not establish movement intention or stimulation timing.
stereoelectroencephalography · continuous decoding · false alarms · brain-computer interfaces · threshold calibration · offline replay
References
3- usesA fixed SEEG decoder separated windows before keypress from rest on later trials in eight patients sci:sha256:bd6c59023a95ca7dc23d6549123fb8e0b3724d75412db49c1e004ce64fc1dd57
We imported exact event-window feature files, event sample indices, source metadata, range hashes, and reader code. We fit new early models and retrieved new continuous score windows to test alarm rates on later data.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analysis uses recordings from OpenNeuro ds004473, version 1.0.2.
- doi:10.1088/1741-2552%2Facae0a
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesCalibrated thresholds removed two silent alarms and missed six sentences in two SEEG replays with a 0.5 s offset allowance
Its motor replay study motivated separate fit, threshold calibration, and later continuous test periods. We applied this design to passive speech listening in a different dataset.
- usesThree consecutive SEEG scores detected 14 of 320 later key responses before keypress after separate early calibration in eight recordings
Used its exact continuous calibration and test scores, fixed models, training features, raw fixtures, source provenance, and reader code. Added a planned causal score persistence comparison with separate early thresholds. The one-score metrics were reproduced exactly.
- usesThree consecutive SEEG scores detected 14 of 320 later key responses after early threshold calibration in eight patients
Supplies the exact fixed model inputs, continuous SEEG scores, test support, source receipts, and reader code. These files permit the new causal persistence comparison. The new one-score outputs equal this prior result exactly.