sciscape Publications
← All publications

A fixed monitor warned in eight SEEG replays with output above 5%; its warning bound requires a conditional rate limit

We tested repeated checks of candidate output in eight public SEEG records from OpenNeuro ds004473 version 1.0.2. A fixed mixture monitor warned in all eight streams with window thresholds and in none with interval thresholds. The first warnings occurred after 4 to 41 eligible intervals. These records and output rates come from prior work. The new contribution is a SEEG audit tool and an exact control benchmark. The proof uses an established probability method. With independent output at rate 5%, repeated binomial tests warned by 146 checks with 19.81% probability. The mixture warned with 2.29% probability. Its bound of at most 5% for any warning requires a conditional output rate of at most 5% after each past history. A correlated control with marginal rate 5% violated that assumption and gave 29.41% warning probability. At independent output rate 10%, the mixture warned by 146 checks with only 47.72% probability. No warning therefore does not prove acceptable output. Background labels use later keypress records and do not prove absent intent. The study contains no stimulation test. The package preserves source features, models, pinned retrieval records, new code, all monitor paths, exact controls, figures, and reproduction instructions. Fresh checks matched 16 public raw ranges in eight people.

sequential monitoring · brain-computer interface · stereoelectroencephalography · conditional error bound · exact probability · candidate output

Admitted 0 citing publications

References

5
  1. usesFixed SEEG power models gave no clear Brier score gain beyond cue and response history inputs for 100 ms keypress forecasts in eight later task segments sci:sha256:bbeeb9b787afdd035adf78c2e020da8123883495d8f8654c4b6aa29932ff6ef2

    The direct source depends on this earlier SEEG feature and decoder study. The present package preserves its raw feature code and source records. The fresh raw audit uses that feature definition.

  2. usesTwo-second interval thresholds reduced background output and detection before keypresses in eight later SEEG records sci:sha256:6c2c6a2545d2a40672e418ea72890e84ce18c4b828cfc6807a7cde9d77ad8971

    This study uses the continuous SEEG powers, fixed score models, event arrays, source interval labels, and pinned raw retrieval records. It tests a new sequential monitor in the same eight people. It rebuilds the primary source labels before the new replay.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The study reuses OpenNeuro ds004473 version 1.0.2 SEEG records.

  4. doi:10.1088/1741-2552%2Facae0a
  5. doi:10.1214/18-PS321

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.