Adding eight SEEG pairs changed mean later probability error in opposite directions under four fixed penalties in six recordings of one film
Mean Brier error was 0.2469 for EOG and ECG alone and 0.2509 after adding eight SEEG contact pairs. The observed combined-minus-control change was +0.0040. The descriptive 95% person bootstrap interval was -0.0224 to +0.0261. The added SEEG inputs gave lower error in 2 of six people. The four fixed penalty checks gave combined-minus-control mean error changes of -0.0283 at C=0.01, -0.0126 at C=0.1, +0.0040 at C=1, +0.0083 at C=10. A smaller C gives a stronger penalty. These checks were fixed in the plan and remain secondary. Training used the early half of the retained film blocks; testing used the later half. The models used four fixed power bands and training-only selection and scaling. The package adds EOG/ECG voltage and features to a public six-person SEEG control set. Complete source checks reproduced every inherited SEEG feature. It includes code, source hashes, all fitted models and predictions, figures, and an exact analysis repeat. The result applies to these readers and one film. It does not establish a neural cause, speech intent, clinical benefit, or stimulation effect.
stereoelectroencephalography · SEEG · electrooculography · EOG · electrocardiography · ECG · brain-computer interfaces · Brier error · later-time prediction · artifact control
References
5- Random splits gave higher mean speech and music block accuracy with eight contact pairs in six SEEG recordings of one film sci:sha256:072f5aa938e2b517feb5005f8060dfbfa31bf4aa3e4a118c8dd327af55fd776f
[Legacy relation: reproduces] A new retrieval of all six complete raw signal files exactly reproduced all 1,053,312 inherited SEEG feature values. This check applies to the feature data, not to every analysis result in the cited publication.
- usesRandom splits gave higher mean speech and music block accuracy with eight contact pairs in six SEEG recordings of one film sci:sha256:072f5aa938e2b517feb5005f8060dfbfa31bf4aa3e4a118c8dd327af55fd776f
This study uses the fixed six-person cohort, SEEG features, source metadata, and retrieval code from this publication. It adds source EOG and ECG inputs and a later-time probability test.
- usesdoi:10.18112/openneuro.ds003688.v1.0.7
The analyses use the pinned OpenNeuro ds003688 version 1.0.7 source data.
- doi:10.1038/s41597-022-01173-0
This paper describes the source clinical intracranial recordings and film paradigm.
- supportsdoi:10.1007/s10548-009-0078-5
This study reports eye muscle artifacts in temporal pole depth recordings, which motivates the EOG control.
Cited by
0 publicationsPublic catalog entries on Sciscape.