The Brier score gain from voltage energy before a pulse was uncertain in eight offline SEEG sessions
We tested whether voltage energy before a pulse helped estimate a wrong stimulation-site reading beyond response scores. We used public STReEF SEEG data from eight people with epilepsy. Each person had four selected sites and 20 reversed-order test pulses. Each error model used only calibration error labels from seven other people. No test labels entered any fit. The site reader had 115 correct readings out of 160. Adding before-pulse energy changed mean Brier error from 0.142813 to 0.141587. The gain was 0.001226. The descriptive 95 percent patient bootstrap interval was -0.002015 to 0.004565. This interval conditions on fitted predictions and does not refit shared donor models. At 80 percent coverage, both models kept 100 correct readings out of 128. The added signal did not improve that result. All 320 source epochs and 421,120 features passed a fresh raw-data rebuild. The package contains code, compact data, source records, fitted models, per-pulse results, figures, and rebuild commands. The mixed recording schedule, reused cohort, and possible artifact limit the result. No live feedback or brain-writing benefit was tested.
SEEG · stimulation-site reading · Brier score · error estimation · selective prediction · voltage energy · brain-computer interface
References
4- usesPulse time gave 80.8 percent site accuracy after recorded contact order reversal in offline tests of 12 sites in each of eight SEEG patients sci:sha256:e5e3c24eac9e3dc4aa378ea67ee4dffac13f99da5cb7a90323baae156c2e4ac6
This work supplied the fixed four-site sample, voltage features, native epochs, source metadata, and raw retrieval code. We reproduced all 160 post-pulse site readings and scores. Its schedule audit defines the limits of the offline split.
- usesSlow SEEG energy before a pulse had a mean rank correlation of 0.164 with later template error in eight STReEF patients sci:sha256:69de30dded254486ecf29150ebe07c78a5b9f3ca73e1487bc58407ae1c9eb2bb
The relation between before-pulse voltage energy and later waveform error motivated this question. We test wrong site readings and added value beyond response scores with a different short window. We did not copy its data or code.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
This study used the eight STReEF SEEG sessions from OpenNeuro dataset ds005448 version 1.0.0; the version-pinned metadata records this DOI and a CC0 license.
- doi:10.1016/j.ynirp.2025.100274
Cited by
0 publicationsPublic catalog entries on Sciscape.