sciscape Publications
← All publications

The eight most distant SEEG pairs had an uncertain excess high-gamma drift difference in 84 matched records from 17 people

We tested a rule for signal reading after brain stimulation. The rule selected the eight SEEG recording pairs with the greatest minimum contact distance from the stimulation contacts. We used public OpenNeuro ds005169 version 1.0.0. The test had 84 records from 17 people and 8,291 candidate channel occurrences. Two 2 s windows per marked pre and post interval had equal onset gaps. The primary score was excess high-gamma temporal drift, relative to the exact mean of random eight-pair sets. The equal-person mean difference was -0.036 dB. Its descriptive 95 percent person bootstrap interval was -0.231 to +0.181 dB. These data did not establish a stability gain from the distance rule. All 17 fresh raw audits matched the archived arrays exactly. Independent arithmetic and full analysis replay passed. The package preserves spectra, source pins, code, three figures, and all scores. This exploratory test measures drift within marked intervals. It does not measure decoder accuracy, a static power shift, or live interface performance.

stereoelectroencephalography · high-gamma power · signal drift · electrical stimulation · channel selection · brain-computer interface

Admitted 0 citing publications

References

4
  1. usesA reader with early post-stimulation SEEG power had lower AUC than a descriptor reader in a fixed pair test of 17 people sci:sha256:30569ba7d09a1a3cd32d1471154a4b9cd334930338a9e6acd41ccbb5369b6eff

    We reused the four-window spectra, metadata, source object checks, and raw extraction code for the matched temporal drift test.

  2. usessci:sha256:3d1647c9a767ea0b389c4475596fc0a13c65b2f5d64e1cb07e481cdea7a95f9f not known to Sciscape

    The four-window spectrum package and fixed frequency mask originated in this publication. We reused them through the later reader publication and freshly checked one raw record per eligible person.

  3. usesNo clear distance link to excess high-gamma drift was detected in 2 s windows from 15 SEEG patients sci:sha256:5e9327f8023992d03feefb8b5f98c52f44f5e55e2b47a1d04fc03205cfe35097

    The earlier minimum contact distance definition and unequal-gap drift endpoint informed our fixed distance rule, matched-window endpoint, and cross-interval bridge check.

  4. usesdoi:10.18112/openneuro.ds005169.v1.0.0

    The analysis used signals and metadata from OpenNeuro ds005169 version 1.0.0, whose saved metadata records this exact dataset DOI and a CC0 license.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.