A voltage gate reduced 70–110 Hz SEEG repair error but exceeded hold error with simulated endpoint faults equal to voltage RMS in 20 patients
We tested a fixed baseline voltage gate for filter state repair after simulated 13-sample gaps at 4096 Hz. The reused public SEEG data were from 20 patients and 1,671 native bipolar channels in OpenNeuro ds005169 version 1.0.0. The forward filter passed 70 to 110 Hz. The primary fault added one early voltage RMS to the first returned sample. With independent signs by gap and channel, mean patient median error was 118.43% of reference RMS with immediate repair. It was 71.91% with the 99th-percentile gate and 55.45% with hold. The paired decrease from repair was 46.53 points, with a descriptive 95% patient bootstrap interval of 26.37 to 78.41. All 20 patients improved over immediate repair. Seventeen had lower error with hold. With unchanged endpoints, the gate raised error from 25.40% to 26.28%. A simulated common-sign fault and a valid voltage step gave identical first decisions in all 80,208 gap-channel pairs. The package preserves exact inputs, hashes, code, scores, decisions, bootstrap draws, and three figures. All 20 source files passed full hash checks. All 10,096,735 saved voltage values matched the sources. An independent recurrence reproduced the gate outputs. The full analysis repeat matched all saved numerical results. This test concerns recorded waveform error under controlled faults. It does not establish neural origin, live artifact recovery, or decoder benefit.
SEEG · signal processing · filter state repair · voltage gate · simulated endpoint faults · brain-computer interface
References
3- usesState correction reduced 70 to 110 Hz error after simulated 13-sample gaps in baseline SEEG from 20 patients with clean endpoints sci:sha256:6e79fa2c0f3fd3bf99e67f05cc78959b6a8c7ec430c7389a9ebd20941a5d553e
We reused its exact 20 patient baseline arrays, gap starts, provenance, and filter repair code. We tested a fixed baseline voltage gate and two fixed gap extensions on the same records. The package preserves the parent manifest and exact import hashes. This is not an independent cohort validation.
- usesdoi:10.18112/openneuro.ds005169.v1.0.0
This study used the selected baseline SEEG files from OpenNeuro ds005169 version 1.0.0; saved file hashes and all analyzed voltage values were checked against the source.
- doi:10.1002/hbm.25749
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesEarly fitted partial state correction lowered expected 70 to 110 Hz error after 13-sample gaps in baseline SEEG from 20 patients with independent endpoint errors of one early voltage RMS
The earlier voltage gate result showed that an endpoint check could reduce full correction error but did not beat hold under its main endpoint fault. This known result helped define the question about partial correction. Its numerical scores were not used to fit weights or to make a direct method comparison.