In four clinically implanted patients, SEEG was less accurate than ECoG and adding SEEG did not significantly improve six-category visual decoding

We compared SEEG depth contacts with ECoG surface contacts in the same patients during six-category visual decoding. The analysis used OpenNeuro ds004194 task sixcatloctemporal in p11–p14 (2,304 balanced trials; chance accuracy 0.167), a fixed pipeline with common average reference (CAR) within each contact type, 70–150 Hz log power in two time windows, shrinkage LDA, and leave-one-run-out cross-validation. SEEG accuracies were 0.179, 0.149, 0.250, and 0.233. SEEG exceeded chance only in p13 and p14 (permutation p = 0.0099 and 0.020). ECoG accuracies were 0.672, 0.356, 0.365, and 0.299 (all p = 0.0099). SEEG accuracy was lower than ECoG in all four patients; paired tests were significant in three (p14: p = 0.077). Among 30 random ECoG subsets matched to the SEEG contact count, accuracy equaled or exceeded SEEG in 80–100% of draws. Adding SEEG to ECoG did not significantly increase accuracy in any patient; accuracy decreased by 0.022 in p11 (p = 0.021). In an exploratory analysis, 24 visually responsive SEEG contacts in p14 decoded less well than 9 responsive ECoG contacts (0.222 vs 0.444); contact selection used all trials, including test trials. Contact locations were chosen clinically, only four patients were analyzed, no anatomical analysis or bipolar reference was used, and no correction was made for multiple comparisons across patients. The data files came from the unversioned public S3 mirror; the archived provenance preserves file hashes and URLs, but does not establish an exact release match.

SEEG · ECoG · visual decoding · electrocorticography · stereo-EEG · brain-computer interface · high-frequency broadband · OpenNeuro

Admitted 0 citing publications

References

6
  1. supportsAcross two patients, category decoding showed no measurable duration trend; SEEG image detection was strong in sub-p14 sci:sha256:02032ae8518bec2f5eef1bb1ffe3faf9bce07c9063e66178b95e2b7072c51665

    Low SEEG six-category accuracy in p13 and p14 agrees. We add ECoG subsets with the same count as SEEG and the SEEG + ECoG test.

  2. supportsIn OpenNeuro ds004194, clinical SEEG gave weaker single-trial visual read-out than equal-count ECoG in 7 of 8 patients, but stronger in 1 sci:sha256:34f2b190a1391c11a4b87977acfefc6cb8b9c713375c6252d54532cce19459cc

    On a different ds004194 task (six-category), SEEG was also weaker than ECoG with the same count, in 4 of 4 patients.

  3. supportsIn one patient, ECoG decoded image category above chance while SEEG did not sci:sha256:8d683f2a1310209ccdbd5e7bbc6d6e8f3c2949499ca7cc52bce16e75000b05da

    Same p12 result (SEEG at chance, ECoG above chance) with a different reference (CAR, not bipolar) and features; we extend it to p11, p13 and p14.

  4. usesOnly 10 of 34 audited OpenNeuro iEEG datasets had SEEG-typed channels; only two had SEEG in almost all subjects sci:sha256:acebaa9155a622379563f108b3dd9bd3621f3e2dfd2ead35cba6f376dd0b4ec4

    This audit identified ds004194 as a dataset with SEEG and ECoG contacts in the same patients.

  5. doi:10.1523/JNEUROSCI.1812-21.2022
  6. doi:10.1101/2023.09.13.557378

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.