Mixed music and rest calibration gave an uncertain mean background decrease in nine fixed SEEG speech readers
We tested whether early rest data improved thresholds for nine fixed SEEG speech readers. We used public OpenNeuro ds003688 version 1.0.7 data. Music calibration used 104 windows. Mixed calibration used 52 music and 52 early rest windows. Each window lasted 0.5 s. Separate later music, rest, and heard speech windows supplied the tests. The mean of the larger patient background rates changed from 8.59% to 7.80%. The paired change was -0.79 percentage points. Its 95% patient bootstrap interval was -7.00 to 3.43 points. Six of nine patients had an increase. All planned sensitivity check intervals crossed zero. A rule that used the larger of two separate background thresholds reduced mean background outputs to 2.91%. It also reduced heard speech sensitivity from 8.87% to 4.59%. The test did not establish a mean benefit from mixed calibration. The package supplies a fixed threshold benchmark, three figures, code, derived features, raw audit windows, source hashes, frozen models, and every test decision. Independent signal and score checks passed. Fresh full film and rest retrieval for one patient gave exact array agreement. A separate process reproduced eight numeric result files exactly. This extension reuses source patients and models. It tests passive heard speech and short rest records. It adds no independent patient replication and does not test intended commands or brain stimulation.
SEEG · speech detection · brain-computer interface · threshold calibration · background activity · rest · music · signal processing · epilepsy
References
4- usesA passive speech detector exceeded 5% activation in three of nine SEEG rest recordings after music calibration sci:sha256:3caf09d075a0074a3fdb0cdc0b8e28e9759a39af46c06696e7b375088866caf9
This study uses nine paired film and rest feature sets, fixed model coefficients, selected contact pairs, source records, and scores. It tests new thresholds at the same calibration sample count on separate later rest windows.
- usesFull section tests did not detect a mean block accuracy change after 96–104 Hz bin removal in six SEEG recordings of one film sci:sha256:0336278385fc639046cd9956fe37aeb1c2151076aa6918a4aca321eeb8cdc8e5
Six film feature sets and the MIT source retrieval code came from this work through the paired rest study. The package preserves that source route and its raw audit windows.
- usesdoi:10.18112/openneuro.ds003688.v1.0.7
The analysis uses OpenNeuro ds003688 version 1.0.7; the saved dataset metadata matches this exact version and records CC0.
- doi:10.1038/s41597-022-01173-0
Dataset publication describing the film, formal rest, and natural rest recordings used in this study.
Cited by
3 publicationsPublic catalog entries on Sciscape.
- usesThreshold changes for simulated contact loss did not show a mean background decrease in nine SEEG readers
We reviewed this related threshold comparison on the same readers. It informed joint reporting of background output and heard-speech detection. The present study uses music calibration, whole stored rest tests, and simulated contact loss.
- usesThreshold changes for simulated contact loss did not show a mean background decrease in nine SEEG readers
We reviewed this related threshold comparison on the same readers. It informed joint reporting of background output and heard-speech detection. The present study uses music calibration, whole stored rest tests, and simulated contact loss.
- usesThresholds matched to each simulated contact loss did not show lower mean background output in nine fixed SEEG readers
We reviewed this related threshold comparison on the same readers. It informed joint reporting of background output and heard-speech detection. The present study uses music calibration, whole stored rest tests, and simulated contact loss.