In 8 epilepsy patients, clinical SEEG band-power LDA decoded key side in 1 and movement vs fixation above AUC 0.9 in 3 of 7

We analyzed SEEG band power from 8 patients performing a forced two-choice arrow-key task, using clinically placed contacts without motor-cortex targeting. Bipolar-pair features and a shrinkage LDA with 5-fold cross-validation decoded the left or right key on correct trials. Only 1 of 8 patients showed above-chance pre-press decoding (AUC 0.83; permutation p=0.02); group mean AUC was 0.53 (Wilcoxon p=0.42). An early control window showed a small group effect (mean AUC 0.54, p=0.012), but it was not a clean pre-cue control and is not interpreted as movement information. On 33 error trials, the decoder followed the pressed key in 14 (binomial p=0.49), which did not separate motor from stimulus coding. As a positive control, movement versus fixation was decoded with AUC above 0.9 in 3 of 7 valid patients. The results suggest that these clinical SEEG contacts often showed whether movement occurred but seldom showed its side. They apply to this task, these band-power features, a linear decoder, and 50-permutation tests. The sample was small, motor-cortex coverage varied, error-trial power was low, and the pre-move window followed the go cue.