An earlier analysis found that mean high-gamma activity (70–150 Hz) in the 0.5 s before mouse movement decoded the chosen left/right side in 7 of 7 patients (mean AUC 0.533; two-sided sign-flip p = 0.016), as a secondary uncorrected result. We tested this hypothesis with the same feature set and decoder in six new OpenNeuro ds006253 SEEG patients, using a pre-registered plan and stopping rule. For each patient, a Ledoit–Wolf shrinkage linear discriminant analysis (LDA) used all channels and one time-ordered split (first 60% of trials for training, last 40% for testing). The primary test found a mean pre-movement AUC of 0.554 (SD 0.083; t-based 95% interval 0.467–0.641), with 5 of 6 patients above chance; the exact one-sided sign-flip test gave p = 0.094, not significant at alpha 0.05. The minimum possible p with six patients was 1/64 = 0.016. One patient was below chance (AUC 0.393). The pooled result for 13 patients was 0.543 (p = 0.013), but includes the seven patients that generated the hypothesis and cannot confirm it. Exploratory choice decoding increased around movement onset and was strongest afterward. An error-trial test in 10 patients (at least five errors on each side) found mean choice AUC 0.551 (two-sided p = 0.19) and could not distinguish choice from stimulus coding. The results indicate near-chance pre-movement decoding in single patients (AUC about 0.55) for this feature set and linear decoder; it is not useful for a BCI without more information. Limits include six new patients, one split per patient without cross-validation, possible non-stationarity, use only of the author's HGA derivative (not raw SEEG, other bands, or channel selection), possible movement-onset timing error, and class imbalance (right-choice fraction 0.24–0.77; AUC is insensitive to balance, but the LDA prior can shift). Choice and stimulus direction coincide on 72% of test trials. Patients sub-01, 05, 08, 10, 11, 16, 17, 18, and 22 were not tested.

stereoelectroencephalography · high-gamma activity · choice decoding · brain-computer interface · pre-registration · shrinkage LDA

Admitted 0 citing publications

References

4
  1. challengesMovement-detection channels did not improve left/right decoding in 7 SEEG patients sci:sha256:ea9de85ea1f67112a62d9c37bc37d715956583be02292b336498319a76806d68

    Its pre-movement choice-decoding result did not pass a pre-registered confirmatory test in 6 new patients (mean AUC 0.554, one-sided p = 0.094).

  2. Movement-detection channels did not improve left/right decoding in 7 SEEG patients sci:sha256:ea9de85ea1f67112a62d9c37bc37d715956583be02292b336498319a76806d68

    [Legacy relation: reproduces] With its unchanged pipeline, we got exactly its pre_move all-channel AUCs for the 7 old patients (0.503 to 0.584).

  3. usesAn unchanged HGA decoder separated movement from pre-stimulus rest in three new ds006253 patients sci:sha256:91065020e0862241d2891d9d196cbc00944481cf51314c19a645e14ac229ea03

    We used its feature extractor (extract_local.py) and its archived features for sub-03, 14, 19 and for the 7 old patients.

  4. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analysis uses features and behavioral data from OpenNeuro ds006253, version 1.0.3 (MetaRDK).