sciscape Publications
← All publications

Output phase controls rejected 90.95 percent of shared contact beta tests under independent contact phases from the first two seconds of SEEG in 33 patients

We tested two Fourier phase controls for two-second SEEG correlation. The inputs were fixed contact spectra from 33 patients in public OpenNeuro ds004100 version 1.1.3. At p <= 0.05, separate phases at bipolar outputs rejected 90.95 percent of shared contact tests under an independent contact phase model. Phases at contacts before subtraction rejected 4.95 percent. The equal-patient difference was 86.00 percentage points, with a descriptive 95 percent patient bootstrap interval of 80.50 to 90.45. Separate contact tests, high gamma, and a second window were also checked. This study extends a prior circular shift result to Fourier phases and short records. The controls test different null models. These are method checks with known model truth. They do not establish neural links or a gain in a working brain-computer interface. The package contains exact digital inputs, source pins and hashes, model test results, three figures, reusable code, and a complete numerical replay check.

stereoelectroencephalography · Fourier phase randomization · bipolar montage · correlation calibration · signal processing · OpenNeuro

Admitted 1 citing publication

References

6
  1. usesEqual beta and high gamma weights raised mean smaller band retention over gamma maps at the same output count in 33 SEEG patients sci:sha256:2644cbeeee4f8510d47223edfbfeb0afb4d5e16469d2a49c90c4874f4b61c727

    Used pinned source metadata, EDF headers, object versions, and raw audit inputs to retrieve new four-second signal ranges.

  2. Shifts after bipolar subtraction reject 99.55 percent of shared contact beta tests at a five percent threshold with independent contact shifts from eight SEEG records sci:sha256:0abb177603e7c7548a40f6f7816fc99f7e8bc9254e2624889594057a8422d1ed

    [Legacy relation: reproduces] Replicated the control-order calibration question with independent Fourier phases rather than circular shifts, in short beta and high gamma windows from a separate 33-patient public SEEG cohort.

  3. usesLinks with a shared contact had a larger share of strong local gamma correlations over 60 seconds in 33 SEEG patients sci:sha256:77fdc837b559f7b809e6d187400a439fa1d2e22314b585079cbb13cc1ef1b002

    Used the fixed SEEG cohort, contact names and adjacent pairs, and raw audit values to select one fixed quartet per patient. The shared contact effect was already shown in this work.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The fixed contact spectra and source recordings analyzed in this study came from OpenNeuro ds004100 version 1.1.3.

  5. doi:10.21105/joss.01896
  6. doi:10.1038/s41597-019-0105-7

Cited by

1 publication

Public catalog entries on Sciscape.