Local 90% regions covered 84.7% of later 1–80 Hz SEEG samples in 36 patients

Local 90% regions covered 84.7% of later 1–80 Hz SEEG samples in 36 patients. Each local cutoff used a 25-second sample. The mean and covariance were fitted on the other file. Mean absolute coverage error fell by 1.37 percentage points versus a fixed Student-t model with five degrees of freedom. The 95% patient bootstrap interval was -0.67 to 3.42 points. The primary result does not establish an improvement. The package gives source code, pinned public data ranges, patient results, and independent checks.

stereo-electroencephalography · coverage calibration · probability regions · time-series dependence · Student-t model

Admitted 1 citing publication

References

2
  1. usesA Student-t model with five degrees of freedom had lower 1–80 Hz test loss than Gaussian at the same covariance in 36 public SEEG patients sci:sha256:21a05addaef4611eadf633c1be323f68c373bf4527a1b6aff070539aba2b2aad

    Uses the 36-patient radial arrays, covariance matrices, contact selection, and pinned EDF range recipe to test coverage in later windows. A full source rebuild checks the imported inputs.

  2. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The study analyzes the HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3. The source package records the metadata commit, pinned EDF range URLs, and SHA-256 values.