Joint selection reduced contact correlation but gave no clear error gain for four SEEG contacts in ten speech recordings
We tested two contact selection rules in ten public SEEG recordings of spoken words. Each rule used four contacts and the same three features per contact. One rule used each contact alone. The other rule added the contact with the largest further ridge fit gain. Earlier trials supplied fitting and penalty selection. The remaining 194 complete trials supplied test scores. The primary mean relative error reduction was -0.11%. The descriptive 95% whole-person bootstrap interval was -2.66% to 2.07%. Five people had lower error, three had higher error, and two had equal error. Mean training contact correlation fell from 0.442 to 0.297. Separate contact scores reduced error by 12.80% against a cue-time model. Joint selection reduced it by 12.58%. These results do not establish equivalence or a neural cause. The test reused a small clinical cohort and assumed the source clock repair. The package includes all used features, model states, test predictions, trial permutations, source records, code, four figures, and replay steps. One fresh source download gave an exact feature match. Independent fits and selection checks passed. This study tests a reading method. It gives no stimulation result.
stereo-EEG · speech production · brain-computer interface · contact selection · ridge regression · speech amplitude · trial validation
References
5- usesEight SEEG contacts reduced mean log speech amplitude test error by 12.1% beyond cue timing in ten recordings with corrected clocks sci:sha256:ded786a796f434af01186591335157992f3d58604e9d224da3b77aa84adf9e37
We use all ten feature files, source metadata, extraction and retrieval code, and the eight-contact reference result. We test matched contact selection rules on the same later trials.
- usesOne pair per named electrode group reduced input correlation but did not establish better sound amplitude readout in ten SEEG listeners at matched pair counts sci:sha256:2a3919f2fbd715f4ec0086469f9582a7b8cb31d3b4d26c0fef20adea38a49b93
We use this result to compare contact correlation with later readout error. The present study tests a different selection rule on spoken-word SEEG.
- doi:10.1038/s41597-022-01542-9
- usesdoi:10.17605/OSF.IO%2FNRGX6
The study used the Dutch word production data released under this OSF record, accessed through the NEMAR nm000371 mirror.
- usesdoi:10.82901/nemar.nm000371
The study used the original NWB files from NEMAR nm000371 version 1.0.0, including a fresh sub-05 retrieval and inherited source retrieval records for the other nine recordings.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesEight selected SEEG contacts lowered log speech amplitude error beyond cue and text controls in ten recordings with repaired time stamps
The ten feature files, source metadata, and extraction recipes supplied the fixed cohort for the new text cue test. Their archived hashes matched every reused input.