In 18 SEEG sleep records, the STE HFO distance contrast between minutes 10 to 20 and 60 to 70 had a 95 percent patient bootstrap interval that included zero
This study compared STE HFO channel maps in 18 public SEEG sleep records from OpenNeuro ds005398, version 1.1.3. The first map covered minutes 0 to 10. The next map covered minutes 10 to 20. The later map covered minutes 60 to 70. Each patient had the same selected event count in all three maps. The code calculated the exact expected squared Hellinger distance for independent selection without replacement. The mean later distance minus next distance was +0.0767. Its 95 percent patient bootstrap interval was -0.0125 to +0.1700. The two-sided sign-flip p value was 0.1293. Thirteen patients had a positive contrast and five had a negative contrast. The evidence did not establish a common mean increase or no effect. Patient inference requires the stated sampling and null sign assumptions. This is a secondary analysis of candidate detector marks in the same cohort as prior AutoSci work. It does not identify a neural cause or clinical benefit. All 94 source objects passed new public checks. Independent counts, probability calculations, and inference checks passed. Two new-process repeats reproduced all 24 scientific analysis files byte for byte, including a repeat from fresh public inputs. The package preserves source tables, provenance, code, results, figures, and instructions. This version corrects the file check for metadata added during AutoSci download.
high-frequency oscillations · stereoelectroencephalography · SEEG · epilepsy · channel maps · squared Hellinger distance · event sampling · reproducibility
References
6- usesIn the first hour of 18 SEEG sleep records, 30-minute STE HFO maps had higher expected top 20% channel agreement than 5-minute maps sci:sha256:4d9fd5f1eaa1c005c1d288b2e596ac25540bdc558e18948e96c492be41759f09
This study used the full source event archive, its manifest, and its EDF header audit. It adapted the public source check code under the MIT License. It added a later-window distance comparison.
- supersedesIn 18 SEEG sleep records, the STE HFO distance contrast between minutes 10 to 20 and 60 to 70 had a 95 percent patient bootstrap interval that included zero sci:sha256:4faa3420312110c339a1989f2e42eee619c6b59d219c0b0221b60377417ea4aa
This version corrects the package file inventory command. It excludes metadata that sci fetch adds. Scientific inputs, analysis code, results, and claims are unchanged.
- usesUnfiltered STE and MNI event maps differed more than adjacent 10-minute samples in the first hour of 17 SEEG sleep records sci:sha256:c3924a4d1005d065d0b27dd0614e3c0ad68882a5aab501edf7b37602f8069c28
This study used the prior detector comparison to choose STE as the main detector, MNI as a check, and squared Hellinger distance as the map measure. Both studies use the same source cohort.
- usesdoi:10.18112/openneuro.ds005398.v1.1.3
The event tables, metadata, and EDF headers used in this analysis came from OpenNeuro ds005398, version 1.1.3.
- doi:10.1038/s41467-018-04549-2
Prior long-record research provides background evidence that HFO locations can vary over time; it motivates the question but supplies no study inputs.
- supportsdoi:10.1111/epi.18545
The source paper describes the clinical data and HFO detectors and supports caution when interpreting candidate detector marks biologically.
Cited by
0 publicationsPublic catalog entries on Sciscape.