One request bounded fixed SEEG score error in eight sessions with reliable replies
We tested a method to send a continuous brain reader score with a stated error limit. The source was public OpenNeuro ds004473 version 1.0.2. We used 67,309 later SEEG windows from eight people. The sender sent four-bit power codes. The receiver requested selected original values once. It released a score only when an outward interval proved its error limit. The main limit was 5 percent of the score standard deviation in early fitting data. Every later window passed. Mean cost was 108.1 bytes, compared with 128 bytes for exact feature transfer. The mean saving across people was 15.5 percent. The descriptive 95 percent person interval was 10.3 to 21.2 percent. At 16 extra bytes per message, the method cost 8.4 percent more than exact transfer. A 1 percent score limit also cost more before message overhead. The earlier binary decision rule met the 5 percent score interval limit in only 9.6 percent of windows on average. The method assumes fixed affine readers, finite float32 features, shared parameters, and reliable ordered replies. The proof gives an error bound for each released score. It does not require independent SEEG windows. The package contains the proof, source recipes, fixed data, all masks and bounds, three figures, code, and checks. Independent wire replay passed 201,927 score checks. Fresh source checks covered all eight people and 28 raw windows. This study adds a score transport method. It does not establish better clinical decoding, stimulation, or radio power.
SEEG · brain-computer interface · score transport · error bounds · feature coding · communication cost
References
6- usesFour-bit SEEG messages saved payload and kept fixed decisions in eight sessions with original values returned on request sci:sha256:c9d787a48def8496c29204ba07a672437b7021c6fcd4bfc77c74ae7c921d0f80
We use its preserved four-bit code implementation and exact-transfer reference.
- usesSelected requests used fewer bytes than full return and kept fixed SEEG decisions in eight sessions with reliable replies sci:sha256:bc82953fdc40a093e4319f4b35521f4bf7fd5a6aeb0ab87ec721786819184343
We use its fixed inputs, source records, and selected binary method as a precision control.
- usesAt a zero threshold, eight-pair SEEG decoders gave a mean of 36.7 outside-guard triggers per eligible minute in eight later task scans sci:sha256:22495a59283fcfea65785cbf2a7a410c3a81dc75e721320a08a5ed114e14bd43
We use its inherited early event feature recipe.
- usesA rule with three scores did not show better detection before key presses at a 5/min early background budget in eight SEEG recordings sci:sha256:4123fe4badcd90fdd5baa89a3bdfb8efdb03e541ba11f571a97f99b1edb9e826
We use its inherited fixed readers and continuous SEEG retrieval recipe.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
Analyzed feature streams and fixed readers derive from this version of the OpenNeuro dataset.
- doi:10.1088/1741-2552%2Facae0a
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.