A fixed-frequency fit supports the fourth HD 12098 signal in TESS sector 85 corrected flux if noise blocks are independent
We compare public TESS visits of the magnetic pulsating star HD 12098 in 2022 and 2024. We fit six published frequencies together. In sector 85 corrected 120-second flux, the component at 183.71535 cycles per day has semi-amplitude 43.2 ± 10.5 ppm. The error uses a covariance model with independent half-day noise blocks. An approximate two-coefficient test gives p = 0.0053 after adjustment for six targets. Sector 58 gives 40.4 ± 5.9 ppm at the same frequency. The later aperture 120-second fit gives 22.9 ± 9.0 ppm and adjusted p = 0.257. The aperture 20-second fit gives 31.9 ± 7.3 ppm and adjusted p = 0.0022. The two cadences share photons. They are not independent detections. A check at 11,738 shared windows does not establish a cadence processing difference. An apparent decrease in the combined multiplet amplitude weakens when frequencies can move. The data do not establish an intrinsic amplitude change. The contribution is a later-visit test of an unexplained component, conditional on the signal and noise model. It does not establish the physical cause or exclude contamination and coherent instrument errors. The package contains all three source FITS files, hashes, provenance, code, results, figures, and reproduction instructions.
HD 12098 · TIC 445543326 · TESS · stellar pulsation · rapidly oscillating Ap stars · time series · noise covariance · reproducible astronomy
References
6- usesdoi:10.1093/mnras/stae431
We use its six sector 58 frequencies to define the targets before flux inspection. Sector 85 provides a later-visit test.
- doi:10.1093/mnras/stad3800
This earlier TESS survey used sector 58 for HD 12098 and discussed a distorted triplet with a nearby mode.
- usesdoi:10.17909/t9-nmc8-f686
Source archive for the exact 120-second SPOC light curves in sectors 58 and 85. Product names and hashes are preserved.
- usesdoi:10.17909/t9-st5g-3177
Source archive for the sector 85 20-second SPOC light curve used in product and matched-window checks.
- doi:10.3847/2515-5172/adb3aa
This study reports high-frequency noise in fast TESS light curves of other targets. It gives context for product checks, not a noise diagnosis for HD 12098.
- TESS 120-second data show a 50–53 ppm peak near 1.201 mHz in HD 217522 in 2026 sci:sha256:b4449003a62fc832a587305fc68e0733acc4a238f628cf28dc3ab87af28d1dee
Related same-passband TESS comparison for HD 217522, a different star. No data or code from that work are reused.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.