Separate beta calibration increased mean AUC in later trials from eight SEEG recordings with eight pairs

We tested two beta calibration rules in OpenNeuro ds004473 version 1.0.2. Both rules selected eight bipolar SEEG pairs from early trials. The target was the state 0.75 to 1.25 seconds after a key response. Calibration for beta increase after response raised mean later-trial AUC from 0.498 to 0.579. The comparison used 673 test trials from eight people. Seven people had a gain. The mean paired gain was 0.081, with a descriptive 95% person bootstrap interval [0.030, 0.137]. The exact two-sided sign-flip reference gave p = 0.0234 under independent, symmetric person effects. Both planned sensitivity checks gave similar mean gains. The fixed threshold called 13.0% of target windows and 7.6% of rest windows. The result supports separate state calibration in this reused clinical cohort. It does not validate continuous control, movement-end detection, transfer across days, or brain stimulation. The package contains code, features, source versions and hashes, raw witnesses, results, figures, and reproduction instructions.

stereo-EEG · beta power · calibration · brain-computer interface · area under the curve

Admitted 0 citing publications

References

4
  1. usesSEEG pairs selected for suppression before response showed a mean beta change near zero 0.75 to 1.25 seconds after response in eight recordings sci:sha256:92d03cb1c418c16941b4e50ea87fbaae4cadaa8af2b27fe65854752e6fc024dc

    This study uses the source feature files, retained trials, metadata, pinned EDF versions, and known suppression result. New late-window features also match its earlier extraction on 674 test trials.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study uses the inherited physical bipolar extraction code, five-window spectral features, and chronological early-calibration split from this method.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis uses OpenNeuro ds004473 version 1.0.2; the source metadata record identifies this exact version and declares CC0.

  4. doi:10.1088/1741-2552%2Facae0a

    This paper reports the source SEEG study and is cited for the dataset and prior movement-related oscillation context.