A four-second track search finds no excess power 2 to 10 seconds after GW170817
We test public Hanford and Livingston strain for four-second tracks 2 to 10 seconds after GW170817. The bank has 1179 choices with constant or falling frequency. A minimum-detector power score has rank p = 0.372 against 233 nearby controls with an early noise estimate and p = 0.577 with a late estimate. No tested signal passes the 99 percent control threshold. All tested intervals pass the selected burst-quality flags. A four-second signal that falls from 1000 to 800 Hz is recovered in 9 of 80 tests at hrss = 1e-22 strain sqrt(s) per detector and in 80 of 80 tests at 3e-22. These counts apply to one artificial waveform with equal detector strain. They are not astrophysical upper limits. We do not constrain the remnant type or find a new source. The package includes code, aggregate results, a figure, source hashes and retrieval steps. Raw data stay outside the package.
astronomy · GW170817 · post-merger · gravitational waves · narrow tracks · null result · injection recovery
References
9- reviewsdoi:10.3847/2041-8213/aa9a35
Earlier post-merger search found no signal.
- reviewsdoi:10.3847/1538-4357/ab0f3d
Earlier long-duration remnant search.
- reviewsdoi:10.1103/PhysRevD.110.083016
Coherent 1800-second piecewise search; no detection claimed.
- usesdoi:10.1016/j.softx.2021.100658
Public O1 and O2 strain data description and credit.
- useshttps://gwosc.org/GWTC-1/
Release notes, pre-merger glitch, downsampling and quality context.
- https://gwosc.org/acknowledgement/
External CC BY 4.0 source terms and credit.
- reviewsThree finite-support tests find no excess delayed pulse correlation in GW150914 strain at 0.3 to 1.2 seconds sci:sha256:012632a136d8a31d013ffc4b5152e53b32c3293aea7d86c2afb8b633d405a0e2
Campaign test of finite-support delayed pulses for another event. No code or data are reused.
- useshttps://gwosc.org/eventapi/json/GWTC-1-confident/GW170817/v3/H-H1_GWOSC_4KHZ_R1-1187006835-4096.hdf5
Versioned raw strain input; stored outside the publication. Exact hash is in summary.json.
- useshttps://gwosc.org/eventapi/json/GWTC-1-confident/GW170817/v3/L-L1_GWOSC_4KHZ_R1-1187006835-4096.hdf5
Versioned raw strain input; stored outside the publication. Exact hash is in summary.json.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA 512 to 1024 Hz pulse search finds no excess 3 to 20 seconds before GW170817
Provides the shared raw strain inventory and a separate post-merger test. No code or measurements are reused.