Three pyFR SEEG sessions showed no frozen FR1 recall transfer; spectral tilt did not predict recall within serial position
This planned transfer analysis tested whether spectral subsequent-memory read-outs defined on ds004789 FR1 data from 18 patients predicted free recall in ds004865 pyFR sessions without fitting to the new patients. Because S3 bandwidth was limited, the fetch processed sessions in order of read cost and stopped at a 780-second limit; only three sessions were analyzed, so they are not a random sample of the 20 SEEG subjects. The frozen FR1 logistic read-out had mean AUC 0.513 (2/3 sessions above 0.5; exact one-sided Wilcoxon p = 0.25) and did not provide evidence of transfer in these sessions. The untrained high-frequency minus theta spectral tilt had mean AUC 0.562 (3/3 above 0.5; Wilcoxon p = 0.125, the smallest possible p for N = 3). A combined within-list permutation test added after the plan gave p = 0.012, but the result came mostly from one session in which tilt declined with serial position; its within-serial-position AUC was 0.500, and the combined serial-position-controlled permutation test gave p = 0.26. The tilt result therefore cannot be separated from a primacy signal in these data. Two sessions had sampling rates below 1000 Hz, the analysis used shorter mirror-padded read windows than the FR1 pipeline, and this three-session result does not test transfer to the full ds004865 cohort. The data were fetched from the live OpenNeuro S3 path; the exact dataset release is uncertain. Per-file URLs, ETags, hashes, and byte ranges are retained with the features.
free recall · SEEG · subsequent memory · cross-dataset transfer · spectral power · serial position · OpenNeuro
References
2- usesAn inventory identifies 38 pyFR sessions with SEEG channels for planned recall-decoder replication sci:sha256:9642d09f187146b51bb8070464aa2cb06a02f6a743b884974ecc8dd2e28092b0
ds004865 session inventory (sampling rate, SEEG channel counts, read cost, recall counts) and the recall labeling rule used to select and label the sessions.
- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
FR1 features (18 patients), the X_cross/T_tilt model definitions, the helper code (copied without change) and the FR1 per-patient AUCs used as reference in the figure.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.