A fixed high gamma SEEG key model gave 48.9 percent mean balanced accuracy with random splits and 48.1 percent on later trials in eight patients

We tested whether random trial splits gave higher response key accuracy than tests on later trials. SEEG means stereoelectroencephalography. We reused 1,988 public trials from eight patients in OpenNeuro ds004473 version 1.0.2. The fixed ridge model used trial order and high gamma power changes at 822 contact pairs. Mean balanced accuracy was 48.90 percent over random splits and 48.13 percent on later trials. There were 100 random splits per patient and condition. The mean difference was 0.77 percentage points. Its descriptive 95 percent patient bootstrap interval was -1.73 to +3.04 points. The exact two-sided sign reversal test gave p = 0.578 under patient independence and symmetric null contrasts. The test did not detect a clear split difference. It does not prove equal performance. The weak key prediction limits conclusions about stronger decoders. This is the same cohort as the earlier feature study. The package preserves powers, labels, every split and test score, primary model fits, code, raw signal fixtures, source hashes, and reproduction instructions. Independent solver and Fourier checks passed. A full repeat analysis matched the results.

stereoelectroencephalography · SEEG · high gamma · response key decoding · ridge regression · random splits · temporal validation · balanced accuracy

Admitted 0 citing publications

References

6
  1. usesMean beta effect rank agreement was 0.599 with task-cell time splits and 0.585 with random splits in eight SEEG recordings sci:sha256:baa5d0d6bf98486cdbaef4255baa36ae904cf260e5693cce7b2fd318be8d3409

    Its comparison of time and random splits for beta maps supplied the related methods question. We tested split choice with held-out response-key accuracy.

  2. Fixed high gamma and beta models gave 48.1 and 48.5 percent balanced accuracy for response keys on later trials in eight SEEG recordings sci:sha256:850514f6ac20d27125ca5b894cd3aa1ec15bf9f72f2a7dc8d52e37a7b947a5bb

    [Legacy relation: reproduces] The forward branch rebuilt its condition-specific early and late splits and matched all 80 applicable condition balanced accuracy scores. This computational repeat used the same archived cohort.

  3. usesFixed high gamma and beta models gave 48.1 and 48.5 percent balanced accuracy for response keys on later trials in eight SEEG recordings sci:sha256:850514f6ac20d27125ca5b894cd3aa1ec15bf9f72f2a7dc8d52e37a7b947a5bb

    We reused its 1,988 trial power arrays and recorded-key tables, raw fixtures, source metadata, pinned EDF range recipes, and extraction code. Its class-balanced ridge model fixed the primary decoder.

  4. supersedesA fixed high gamma SEEG key model gave 48.9 percent mean balanced accuracy with random splits and 48.1 percent on later trials in eight patients sci:sha256:089b1b76ad63390f9d49e49923e3fa2d75fc331b62cd4329e51400976b32fdc7

    This package adds all eight raw fixture index files to its internal file manifest. AutoSci preserved these files in the first archive. Both versions give the same scientific results.

  5. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis used the recorded trials and source data from OpenNeuro ds004473 version 1.0.2.

  6. doi:10.1088/1741-2552%2Facae0a