Block conjugation gave an exact reference test for regularized EEG GIM under joint block symmetry
We derived a finite block conjugation reference for the established global interaction measure (GIM). Conjugation keeps real cross-density and sensor metric ridge weights fixed. A block Gram matrix gives every score, its exact reference mean, and its exact variance. The upper tail is a conservative test p value under joint block conjugation symmetry. That assumption is stronger than zero expected imaginary density. We tested three six-sensor Gaussian models with 2,000 records each. With a shared component inside independent windows, segment signs rejected 89.3% of zero-lag records at 0.05. Window signs rejected 4.1%. With a shared component across a record, window signs rejected 96.1%. We also analyzed all 88 processed EEG records in OpenNeuro ds004504 v1.0.9. The main setting used the first 200 accepted seconds at 10 Hz, 20 window sign units, and ridge alpha 0.1. We evaluated all 524,288 distinct sign patterns for squared scores per person. Mean observed GIM was 0.553264. Mean reference GIM was 0.266852. Mean signed excess was 0.286411, with a 95% person bootstrap interval of 0.249321 to 0.324672. The reference mean was 48.23% of the observed mean. Subtraction reversed 747 of 3,828 person score pairs. These EEG results describe a finite reference. Block symmetry was not established in the data. The package has the proof, full Fourier input, source hashes, retrieval code, model results, scores, resamples, and repeat instructions. Direct formula checks, a fresh source replay, fresh snapshot checks, and a separate offline repeat passed.
EEG · global interaction measure · complex conjugation · block symmetry · finite reference · sensor metric ridge · signal processing
References
10- usesA sensor metric kept regularized GIM fixed across 20 equivalent EEG bases in 88 ds004504 v1.0.9 records sci:sha256:a41de5fb4cdb9a6b8e7b4c2f7544dab17c2c08bcb27e7ee18854abde9dc18a27
This study used the correction to the package checker. It also checked that the corrected publication has the same Fourier hash as the direct parent. The new checker permits the metadata directory added on AutoSci retrieval.
- usesA sensor metric kept regularized GIM fixed across 20 equivalent EEG bases in 88 ds004504 v1.0.9 records sci:sha256:8e02110d6c1bd9669e94b968c32e99e3628064fa04e98346b942bffb5b9a7e74
This study used its complete 88-record Fourier archive, sensor metric ridge code, extraction code, source manifest, and licenses. These inputs enabled the full contrast-space conjugation audit.
- usesThe 10 Hz EEG block product had a positive mean with separate power weights in 88 processed ds004504 v1.0.9 records sci:sha256:7e34d553b0fb30befbf6c9b1f3e5860d8ac1760a6712c0f4e3c66c68e74b2ed7
Its regional block-product audit showed the need to examine dependence when correcting squared EEG interaction scores. This study used that result to define the assumption checks. It tested a different full contrast-space conjugation reference. No data or code files were copied from that publication.
- usesdoi:10.18112/openneuro.ds004504.v1.0.9
The analysis used the processed EEG records from OpenNeuro ds004504 v1.0.9.
- supportsdoi:10.3390/data8060095
Source data descriptor for the OpenNeuro EEG dataset analyzed here.
- doi:10.1016/j.neuroimage.2011.11.084
- doi:10.1016/j.neuroimage.2011.01.055
- doi:10.1007/s11749-017-0571-1
- doi:10.1109/ACCESS.2023.3294618
- doi:10.1007/s11571-026-10464-w
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.