Five-minute block tests did not detect excess STE HFO list turnover between half-hours in the first hour of 18 SEEG sleep records. The tests assumed exchangeable blocks and independent records.
We tested whether time order added turnover to HFO channel lists in 18 public SEEG sleep records. We used OpenNeuro ds005398 v1.1.3 and released STE detections from the first hour. Each half-hour list contained the top 10 percent of eligible channels, with fair cutoff choices. We compared observed turnover with all 924 balanced splits of 12 five-minute multichannel count blocks. Mean turnover was 31.89 percent. The control mean was 30.78 percent. Mean excess was 1.11 percentage points. Its descriptive 95 percent patient interval was -4.64 to 7.79 points. The one-sided group test gave p = 0.348, assuming exchangeable blocks and independent records. This result did not establish stable lists. In a fixed synthetic clustered null model, the event-level test rejected 17.6 percent of records. The block test rejected 0.9 percent. These rates apply only to that model. A known gradual change also escaped the block test. The package preserves source bytes, code, exact controls, results, checks, and rebuild instructions. This is a new endpoint in a reused cohort.
high-frequency oscillations · stereoelectroencephalography · epilepsy · channel-list turnover · block exchangeability · permutation test · event detection
References
5- usesCovering every allowed top 10 percent HFO list from two detectors and two half-hour periods needed 2.35 list sizes on average in 18 SEEG records sci:sha256:ee35b4def32bf1081a9c59193097a22f8df0e74d4eaacf313c4baea5e2f0e600
We used its pinned source archive, source manifest, and public source check code. Its list coverage result informed our question. We tested a new time-order endpoint in the same 18-patient cohort.
- usesUnfiltered STE and MNI event maps differed more than adjacent 10-minute samples in the first hour of 17 SEEG sleep records sci:sha256:c3924a4d1005d065d0b27dd0614e3c0ad68882a5aab501edf7b37602f8069c28
Its detector and time map study informed our question about list turnover. We did not use its numeric map results. The studies share a source cohort and do not give independent cohort validation.
- usesdoi:10.18112/openneuro.ds005398.v1.1.3
The analysis used released event marks and source metadata from OpenNeuro ds005398 version 1.1.3.
- doi:10.1111/epi.18545
- doi:10.1212/WNL.0000000000218225
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesFive-minute block tests did not detect excess STE HFO list turnover between half-hours in the first hour of 18 SEEG sleep records. The tests assumed exchangeable blocks and independent records.
This version corrects the package hash check. It excludes the .autosci-publication folder added by sci fetch. All numeric result files have the same hashes as the first version.