Removing six seconds with high beta power reduced mean seizure-onset label AUC for 80 to 150 Hz power concentration by 0.043 compared with shifted removal in 34 SEEG patients with two 60 s clips each
This study tested whether high-gamma power concentration depends on seconds with high beta power. It used public OpenNeuro ds004100 version 1.1.3 data from 34 SEEG patients. Each patient had two 60 s interictal clips. There were 3,325 bipolar pairs and 251 seizure-onset pairs. For each pair, the test removed its six highest beta-power seconds. It compared the remaining 80 to 150 Hz concentration with removal after 59 circular shifts of the same masks. Mean seizure-onset label AUC was 0.661 after aligned removal and 0.704 after shifted removal. The paired patient mean difference was -0.04346. Its 95 percent patient bootstrap interval was -0.06958 to -0.01972. A two-sided patient sign-flip test gave p = 0.001005. This test assumes independent patients and null sign symmetry. The within-name-group difference was smaller, and its interval included zero. The result shows time coincidence between label separation and high beta power. It does not identify oscillations, spikes, or artifacts. All 72 raw prefixes and 221 metadata files were checked against pinned public sources. The fresh rebuild matched all 748 archived power-array fields. An offline rerun reproduced all statistical files and score arrays. The package preserves the local plan, source records, powers, selectors, all shifted scores, code, figures, independent checks, and reproduction commands.
SEEG · epilepsy · high-gamma power · beta power · power concentration · AUC · circular shift · intracranial EEG
References
4- usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50
This archive supplied the fixed 34-patient cohort, window-power extractor, pinned raw retrieval records, and original concentration result. We rebuilt all powers from the public prefixes. We added beta-selected time removal and matched circular removal controls.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
We used its EDF decoder, contact quality rules, local bipolar pair rules, and metadata builder through the concentration archive. The inherited source_io.py and source_prepare.py hashes match the original code/analyze.py and code/prepare.py files.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset used: HUP iEEG, OpenNeuro ds004100 version 1.1.3; the saved metadata identifies this exact release and its CC0 license.