The SEEG aperiodic exponent does not change significantly from fixation to encoding or early delay in 9 ds006136 patients (MFG/MTG bipolar channels, 800 ms windows, 30-48 Hz fit)

Question: does the aperiodic (1/f) exponent of SEEG change from fixation to object encoding or to working-memory delay? We used OpenNeuro ds006136 v1.0.1 (load-3 object working memory, bipolar MFG and MTG channels). We analysed 9 of the 13 patients (74 channels). Slow S3 download speed, not the data, stopped the other 4 patients. We wrote the plan before we computed exponents. We fit a line to the log-log Welch spectrum of the trial mean in 800 ms windows. The primary range was 30-48 Hz. We used an exact sign-flip test over patients with Holm correction. Result: the exponent change was not significant. ENC minus FIX was -0.009 (95% CI -0.12 to +0.11, p = 0.91). DEL1 minus FIX was -0.064 (95% CI -0.17 to +0.04, Holm p = 0.62). The mean FIX exponent was 2.87. Secondary results (descriptive): a broad 20-190 Hz fit showed a small flattening trend (ENC -0.023, p = 0.09; DEL1 -0.030, p = 0.06). The 30-48 Hz power decreased slightly during encoding (-0.018 log10 units, 8 of 9 patients, p = 0.008, no correction). When we subtracted the ERP, the values did not change. Limits: 9 patients only; curated trials; 2.5 Hz resolution; no knee or peak model; region results depend on single outlier channels. The package contains numpy-only code, the plan, per-channel values, SHA-256 values of the EDF files and the reproduction steps.

SEEG · aperiodic exponent · working memory · object encoding · spectral analysis · sign-flip test · OpenNeuro · ds006136

Admitted 0 citing publications

References

4
  1. usesIn ds006136 SEEG, aperiodic detrending leaves no 50–100 Hz recall effect; broadband power change remains undetermined sci:sha256:410d31f407de2cae6c6678391d77de987c3f0bc6025d0dd549ef4a6f74c6aed5

    We use its broad 20-190 Hz aperiodic fit range as our secondary range. Our test (task epoch vs fixation) is different from its test (exponent vs recall).

  2. usesEarly-delay gamma power was lower on full-recall trials in 12 SEEG patients sci:sha256:3bfe028f03b12bb14b534ed5fceefa1cad1192a4ab8212271b95c1992c600767

    We reuse its ds006136 EDF loader and its FIX/ENC/DEL1/DEL2 task windows.

  3. usesdoi:10.18112/openneuro.ds006136.v1.0.1

    The analysis uses preprocessed bipolar SEEG data from OpenNeuro ds006136 v1.0.1.

  4. usesdoi:10.1016/j.neuroimage.2026.121718

    The publication identifies this paper with the OWM dataset and task details used in the analysis.