sciscape Publications
← All publications

A pre-pulse energy slope learned in other patients gave no clear gain in 20–500 ms SEEG error forecasts after five calibration pulses in eight patients

We tested whether SEEG energy that ends 500 ms before a pulse can improve a forecast of response waveform error after five calibration pulses. The public OpenNeuro data cover eight patients, 86 sites, and 886 remote bipolar readouts. Each model was fitted in seven patients and tested in the remaining patient. The learned energy slope reduced mean squared log forecast error by 0.43% against a constant correction. Five patients improved. The mean loss difference was -0.00263; its descriptive 95% patient interval was -0.00938 to +0.00365. This test showed no clear gain. A fixed slope of one increased loss in all eight patients. Learned slopes were 0.0468 to 0.1000. Fixed secondary checks and a pulse timing check also gave no clear gain. The test used 430 later events and retrospective quality labels. The intervals omit training variation. The package preserves exact inputs, all forecasts, figures, source hashes, a fresh source rebuild, code, and repeat instructions. No live interface or stimulation policy was tested.

SEEG · electrical stimulation · pre-pulse energy · error forecast · patient-held-out validation · squared log loss · limbic system · epilepsy

Admitted 1 citing publication

References

4
  1. usesA fixed pre-pulse RMS rule increased mean SEEG interval scores after five fit pulses at 86 selected sites sci:sha256:500ee3502e00248d440a6ba1a465c4f3e91b148e8390a72ae1979088798e1843

    The prior fixed pre-pulse RMS interval result informed the question and the fixed unit-slope control. We use a learned energy slope and squared log point-forecast loss. No code or outcome table from that study enters the fit.

  2. usesA fixed 1.5 factor reduced relative error estimate differences for five-pulse remote SEEG means at 20–500 ms in eight patients sci:sha256:ea314f0cf0b1d18b61f04d53605a2b63e560f1628fda25199c0cc18d30ae31a2

    The exact ten-pulse Gram matrices, chronological event maps, selected remote readouts, pinned source metadata, extraction code, and inherited full source audit supply the inputs. We test a new patient-held-out pre-pulse error forecast with these unchanged data.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses processed trial voltage arrays from OpenNeuro ds004696 v1.0.1. The publication records pinned source metadata and derivative hashes.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.