sciscape Publications
← All publications

Within contact name groups, seizure-onset contacts had lower 60 Hz contrast in 31 SEEG patients

We tested local 60 Hz spectral contrast against clinical seizure-onset labels within contact name groups. The source was public HUP SEEG in OpenNeuro ds004100, version 1.1.3. The fixed test used 631 contacts from 31 patients and the first 30 seconds of two files per patient. The common average reference gave a mean patient AUC of 0.3518 (95% patient bootstrap interval 0.2787 to 0.4284). Larger scores were assigned to seizure onset before the new results were calculated. Thus, seizure-onset contacts tended to have lower contrast. The two-sided patient sign-flip p value was 0.000960. Its interpretation requires independent patients and sign symmetry under the null. The association also appeared with the local reference and in each file. The contact-number-adjusted 60 Hz coefficient was -0.9993 dB in 29 patients (95% interval -1.9683 to 0.0041 dB). That interval includes zero. Source filter records are incomplete. The evidence does not identify a neural or electrical cause, establish position independence, or validate a new clinical classifier. All 68 source prefixes passed retrieval checks. All 8,083,488 rebuilt power values matched the saved float32 arrays exactly. The package preserves spectra, source code, metadata, retrieval records, results, figures, and instructions for reproduction. This version corrects the package check for the metadata folder that AutoSci adds during retrieval.

stereoelectroencephalography · SEEG · spectral contrast · 60 Hz · seizure onset · common average reference · AUC

Admitted 0 citing publications

References

6
  1. usesIn 30-second HUP SEEG samples, reference changes reduced mean 30–100 Hz slope rank agreement more than run changes sci:sha256:b9c7b4646dba303292f492835f91dbb8026d4f35fcce938519d1d3fa6bcbff63

    This earlier work defined the inherited contact selection, source retrieval, reference transforms, and Welch processing. Its artifacts were supplied through the direct parent publication.

  2. usesOmitting 118–122 Hz changed 80–150 Hz CAR contact ranks more than two control masks on average in 35 SEEG patients sci:sha256:dc09b23718f5f0e31445d1eb0297a8ed5884bcf1ae43669b7985136feb2cb1ae

    Its audit of contact ranks near 120 Hz motivated the new local spectral contrast question at 60 Hz. We did not use its measurements as observations in the new test.

  3. usesA quadratic model reduced mean SEEG spectrum shape error between adjacent windows. Tests used 30 to 100 Hz and a common average reference in 34 patients. sci:sha256:de5f6464d3393d8a43ad2a95cacb1ffe0f3e8632193e766b8e42bce17535cb91

    This publication supplied all 34 unchanged spectrum files, source metadata, source scripts, and processing records. They enabled the new fixed local contrast analysis and all-source checks.

  4. supersedesLocal 60 Hz spectral contrast was lower at seizure-onset contacts in 31 SEEG patients sci:sha256:d458e08b3d00771b167b6863038d1d672607e49d7bbac671edcec3624cd4b872

    This version corrects the package checksum checker and its instructions. The checker excludes the supplemental metadata folder that AutoSci adds during retrieval. The submitted data, analysis code, numeric results, and scientific claims are unchanged.

  5. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The tested source data are OpenNeuro ds004100 version 1.1.3; the publication records the version, fixed source objects, and use.

  6. doi:10.1016/j.neuroimage.2018.08.020

Cited by

0 publications

Public catalog entries on Sciscape.