Under independent, symmetric patient differences, a test detected no beta AUC gain over baseline across conditions in eight SEEG patients
We tested response-key decoding with beta power in public OpenNeuro ds004473, version 1.0.2. The test used eight SEEG patients, 1,988 response trials, and 822 bipolar pairs. A fixed linear ridge decoder trained in one task condition and tested in the other condition. Each patient score averaged both transfer paths. Mean response-change AUC was 0.50372. Mean pre-cue baseline AUC was 0.48657. The mean paired gain was 0.01715. The exact two-sided patient sign-flip p value was 0.609375. The test assumes independent patients and symmetric differences under the null hypothesis. It did not detect a gain at the planned 0.05 level. A descriptive patient-resampling interval was -0.02385 to 0.06568 AUC units. The result applies to the fixed model, band, windows, and records. It does not prove equivalence or absent beta information. The package contains checked response targets, source powers, fitted models, test scores, resampling assignments, source versions, and reproduction code. An exact complete repeat and independent fit checks passed. A raw source check covered 3,614 powers from one trial per patient. Full raw file hashes were not verified. Cue and key direction are closely related. The test does not isolate a motor cause or predict a future movement.
stereoelectroencephalography · beta power · response-key decoding · condition transfer · ridge regression · area under the curve · OpenNeuro ds004473
References
3- usesTwo references gave 33 stable beta loss labels each and shared 21 under a 1 dB rule in OpenNeuro ds004473, version 1.0.2 sci:sha256:c079974997528aff1b762b9f6cf35144d660cbb33285ade3a4de59cb6ee4f33b
We used its trial beta powers, trial audits, pair identities, source metadata, and raw retrieval records. These inputs supported the response-key transfer test. We checked all 155 archived files. We independently rebuilt baseline and response powers for one trial per patient.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
This is the exact OpenNeuro dataset version used for the archived signal records and trial powers.
- doi:10.1088/1741-2552%2Facae0a
Cited by
1 publicationPublic catalog entries on Sciscape.
- A fixed decoder of 65 to 90 Hz power changes gave mean response key AUC 0.49190 across instructions in eight SEEG patients
[Legacy relation: reproduces] This study used the fixed response-key decoder and instruction transfer design. All 16 primary beta path AUC values matched the prior study exactly. The new tests compared gamma change with beta change and gamma baseline.