sciscape Publications
← All publications

Separate scales for 16 slow modes increased mean relative SEEG forecast error at 20–500 ms in eight patients after contact order reversal

This test used public SEEG data from eight STReEF patients and 96 conditions. Five early pulses set each forecast. Five later pulses tested it after recorded stimulation contact order reversed. Separate scales for 16 slow DCT modes increased mean relative voltage error by 0.80% against one shared scale. The target was strict 20 < time < 500 ms. Seven patients had higher error. The descriptive 95% patient bootstrap interval for the increase was 0.24% to 1.23%. The primary sign-flip reference gave p = 0.03125 under independent and sign-symmetric patient differences. The score gave equal readout weight within conditions and equal condition and patient weight. With early power error weights, the mean increase was 0.074%, and its interval included zero. The sample was reused and exploratory. Time and contact order effects cannot be separated. The package supplies an oracle risk proof with explicit assumptions, four figures, code, exact compact inputs, all scores, and repeat instructions. All 960 raw range hashes and 147 metadata hashes matched public sources. A fresh raw rebuild gave exactly equal coefficients. Independent formula and waveform checks passed. A full numeric replay matched all 21 main output files. This test does not establish full-voltage or live interface performance.

stereoelectroencephalography · brain stimulation · voltage forecast · calibration · DCT · component scales · forecast error

Admitted 1 citing publication

References

5
  1. usesA scale from five early pulses reduced full template SEEG error at 20 to 500 ms after contact order reversal in eight people sci:sha256:c50236eb3980bc5de34015c4d5cd7787844c23bfd051cf18a9adcfe20685512d

    We adapted its early pulse variance rule to one shared condition scale and separate mode scales. Its one-scalar-per-readout rule is also retained as a reference on our projected target. Its published native-voltage scores are not directly compared with these scores.

  2. usesA temporal voltage correction with alpha = 1 increased mean SEEG forecast error after contact order reversal in eight STReEF patients sci:sha256:d6181fb001bbe8600d42bd097ccf08002576024e09a7c8bf28a20879663a54e5

    This publication supplied the fixed metadata sample, 16-mode coefficient inputs, source metadata, pinned range hashes, cosine transform, and retrieval checks. We kept two target windows, rebuilt every selected input from public raw ranges, and tested component scales. No new patients were added.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The eight-patient SEEG sample and source metadata came from this exact OpenNeuro release.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6

Cited by

1 publication

Public catalog entries on Sciscape.