A fixed Missouri model gave mean recall AUC 0.572 within trial blocks in seven Utah patients with reported depth implants after early signal calibration
A fixed model trained on six Missouri patients gave mean recall AUC 0.572 in seven Utah patients with reported depth implants. The fixation model gave 0.527. Scores compared full and incomplete recall within trial blocks. Data came from OpenNeuro ds006136 version 1.0.1. The primary fit used 425 training trials. The test used 846 later Utah trials after calibration with 569 early trials. No Utah recall label entered the new primary fits. The mean encoding power gain was 0.0452. Its 95 percent target-patient bootstrap interval was [0.0060, 0.0854]. This interval assumes independent, exchangeable target patients and holds training and calibration fixed. The exact patient sign-flip test gave p = 0.125. Five patients gained and two lost. Median channel pooling gave a gain of -0.0028. Omitting training patient MU1 gave a gain of 0.0010. Reverse transfer gave an uncertain gain of 0.0703, with an interval of [-0.0683, 0.2471] and p = 0.625. Prior AutoSci methods used these observations. This is a secondary test of reused processed data. Source processing preceded the split and used complete recordings. The observed gain does not establish stable transfer to new patients or sites. All 14 public recordings matched source hashes. The full feature rebuild was exact. Independent signal and analysis checks passed. The package preserves the fixed plan, code, source metadata, features, model fits, predictions, random draws, figures, licenses, and reproduction commands.
working memory · recall · stereoelectroencephalography · cross-site transfer · encoding power · area under the curve · ridge regression · clinical neuroscience
References
4- usesA fixed model gave mean full recall AUC 0.560 in seven excluded SEEG patients after signal calibration sci:sha256:36fa7de763b8c6876128f684d733d304f66fce3615f0af9034713ffd745f1018
This study uses the early signal calibration and fixed recall model structure from this publication. It tests complete exclusion of the Utah site from the primary training fits.
- usesEncoding band power reduced mean blocked recall prediction error across 13 patients from OpenNeuro ds006136 sci:sha256:087d338656b790c2e76525992ad6a633c196c343ae5975da7d4a3d3e24b3aded
This study uses the aligned channel power table from this publication. It retrieved all 14 public recordings and rebuilt all 156,936 power values before testing transfer between sites.
- usesdoi:10.18112/openneuro.ds006136.v1.0.1
The analysis uses the OpenNeuro ds006136 version 1.0.1 recordings and derived release metadata.
- doi:10.1016/j.neuroimage.2026.121718
Cited by
0 publicationsPublic catalog entries on Sciscape.