sciscape Publications
← All publications

Six SEEG channels showed lower spontaneous band-power dimensionality than six ECoG channels in 16 epilepsy patients, with unmatched spatial spread

For brain-computer interfaces that read band power, the number of independent signals per channel sets a useful channel count. We compared SEEG depth and ECoG surface channels in the same patients and at the same channel count using 60 seconds of NREM sleep from OpenNeuro ds007119. All 103 listed subjects were read; 16 patients had at least six non-overlapping normal bipolar channels of each type. For 70–110 Hz envelopes, six SEEG channels had median participation ratio (PR) 5.16 versus 5.57 for ECoG; SEEG PR was lower in 14/16 patients (paired sign-flip p=0.0011). The PR deficit from a circular time-shift null was 0.780 versus 0.354 effective channels (p=0.00077; median deficit ratio 2.21). For 4–12 Hz, PR was 4.786 versus 5.640 (lower in 16/16, p=3×10⁻⁵), with deficits of 1.120 versus 0.276 (p=4×10⁻⁵; ratio 4.05). With ten channels in five patients, the 70–110 Hz PR difference was absent (8.808 versus 8.831, p=0.69); the 4–12 Hz comparison was lower for SEEG in all five (p=0.062). Both channel types remained near the independent-signal ceiling. Spatial spread was not matched: SEEG channels came from fewer leads and had smaller contact spacing than ECoG channels drawn from grids and strips. The findings concern channels as implanted, not tissue per unit distance. They describe 60 seconds of spontaneous NREM activity in epilepsy patients; PR measures redundancy, not task-related or decodable information. The ten-channel analysis included only five patients.

SEEG · ECoG · band power · effective dimensionality · participation ratio · intracranial EEG · neural signal redundancy · NREM sleep · epilepsy · brain-computer interfaces

Admitted 1 citing publication

References

3
  1. usesIn NREM sleep, SEEG envelope correlation did not decrease from contact step 2 to 6 sci:sha256:eb389b430b51c32f98528a9b60f898871b5a1a6e11491a4dea68c32da04418cb

    Adapted the EDF/S3 byte-range reader (code/hg_corr.py) and used its finding that most ds007119 SEEG contacts lack coordinates to choose a coordinate-free design. Our result extends its pairwise step-2 correlation finding (SEEG > ECoG) to multi-channel effective dimensionality at matched channel count.

  2. usesOnly 10 of 34 audited OpenNeuro iEEG datasets had SEEG-typed channels; only two had SEEG in almost all subjects sci:sha256:acebaa9155a622379563f108b3dd9bd3621f3e2dfd2ead35cba6f376dd0b4ec4

    The channel-type audit identified ds007119 as a dataset with SEEG and ECoG channels in the same patients.

  3. usesdoi:10.18112/openneuro.ds007119.v1.0.0

    The publication analyzed NREM sleep EDF recordings from OpenNeuro ds007119 version 1.0.0. Saved version-pinned metadata records this dataset DOI and a CC0 license.

Cited by

1 publication

Public catalog entries on Sciscape.