Under fixed prediction, signed 10 ms covariance reduced mean error by 1.89 percent for bipolar SEEG between shafts in 19 selected patients at 1–40 Hz
We tested whether signed lag covariance repeats after local contact subtraction. We used 19 selected public SEEG records from OpenNeuro ds003876 version 1.0.2. At 1 to 40 Hz and a 10 ms lag, the fixed signed model reduced mean later covariance error by 1.89 percent. Only bipolar links between different named shafts were used. Error fell in 13 patients. It rose in six patients. The patient bootstrap 95 percent interval was 0.64 to 3.26 percent under independent, exchangeable patient sampling. All ten fixed checks had positive means. Fresh pinned-source rebuilds matched all 19 covariance files exactly. An offline repeat matched all results. This targeted follow-up uses the same cohort as prior work. The result supports repeatable recorded covariance structure under the specified reference control. It does not establish neural causation, whole-process time reversibility, or clinical value. The package preserves code, inputs, source versions, one raw prefix, patient results, uncertainty draws, figures, and reproduction instructions.
stereoelectroencephalography · bipolar montage · lag covariance · signed covariance · reference control · epilepsy
References
7- usesSigned 10 ms covariance gave a mean patient error reduction of 3.56% in 19 selected SEEG records filtered at 1 to 40 Hz sci:sha256:a2fcdd0f9017eb9a4c59ed0d7602b9e8f5a0bce5d0e0055ca22efddefe681576
We used the 19 contact covariance files, raw EDF prefix, source pins, metadata, and extraction code. We added bipolar transforms and a mask for links between shafts.
- usesdoi:10.18112/openneuro.ds003876.v1.0.2
Source dataset, version 1.0.2; its fixed source versions and hashes are recorded in the preserved provenance.
- doi:10.1093/brain%2Fawac300
- doi:10.1101/2021.10.15.464594
- doi:10.1038/s41593-021-00901-w
- doi:10.1093/braincomms%2Ffcae165
- doi:10.1016/j.clinph.2006.05.032
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA contact metric preserved 10 ms signed lag prediction gain across three equivalent shaft contrast bases in 19 SEEG records at 1 to 40 Hz
This publication supplied the signed covariance prediction setting, 19 contact covariance archives, the raw fixture, metadata, source pins, input hashes, and unchanged extraction code. The new analysis uses the same patient records and reproduces its adjacent mean gain before it tests equivalent contrast bases.