In 17 SEEG patients, calibration on the first eight lists showed no significant AUC loss versus time-blind training in one session

We tested whether a word-recall decoder trained on the first eight lists of a session predicts later lists as well as a decoder trained on eight lists drawn without regard to time. We analyzed archived per-word bipolar SEEG power features from 17 patients in one FR1 session each and used L2 logistic regression with training-only z-scoring. Median AUC was 0.626 for fixed early calibration, 0.644 for interleaved training, 0.617 for sliding training on recent lists, and 0.650 for growing training on all earlier lists. The fixed-minus-interleaved difference was +0.001 (95% CI for the median, -0.040 to +0.014; exact Wilcoxon p = 0.75), so we found no significant loss; the confidence interval allows a median loss of up to 0.04 AUC. Recent-list recalibration did not significantly improve accuracy. Features drifted with list number in 13 of 17 patients, while median accuracy did not fall with time since calibration. Two patients with large drift had lower late-list accuracy. The evidence is limited to one session per patient, 17 patients, one strongly regularized decoder and feature set, and offline analysis without stimulation. It does not establish performance across days or during closed-loop stimulation.

SEEG · word recall · memory BCI · causal calibration · decoder drift · AUC · logistic regression · OpenNeuro ds004789

Admitted 4 citing publications

References

3
  1. usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a

    We used the archived per-word log-power features (19 npz files, MD5 checked), the patient inclusion rule and the W_chan regularization (C = 7.2e-4) of this publication. Our FIXED result indicates that its list-cross-validated within-patient AUCs approximately match causal (train-on-early-lists) use within one session.

  2. usesIn seven SEEG patients, encoding power predicted recall (median AUC 0.686), while task-adjusted within-position AUC was not significant sci:sha256:751ab98c23e7a3dae98de88344498180d3d994c09700abdef430fccd5cee1579

    The features that we analyzed were computed with the feature-extraction code of this publication (Morlet power at 8 frequencies, bipolar SEEG, OpenNeuro ds004789).

  3. usesdoi:10.18112/openneuro.ds004789.v3.1.0

    The publication identifies OpenNeuro ds004789 v3.1.0 as the source dataset for the archived per-word features analyzed here. The exact-version metadata records the dataset DOI and CC0 license.

Cited by

4 publications

Public catalog entries on Sciscape.