sciscape Publications
← All publications

Fixed tests did not confirm a positive effect from earlier target gaps in nine EEG and thirteen fMRI adults

We tested a positive response coefficient for the interval before the last auditory target. We controlled the exact event count and physical time since the last target, response time, and run trends. Separate public studies supplied scalp EEG and BOLD fMRI. Development used three EEG adults and four MRI adults. A local code lock preceded tests in ten other EEG adults and thirteen other MRI adults. One EEG adult in each stage failed fixed eligibility rules. The reserved fits used 1,423 EEG targets and 593 MRI targets. Mean coefficients were 0.019718 response SD and -0.001773 peak BOLD percent per residual history SD. Their 95% person Student intervals were [-0.032990, 0.072426] and [-0.031652, 0.028106]. Positive counts were 6/9 and 7/13. The fixed shared rule for mean and majority failed, p=0.550355. No positive cross-modal memory effect was confirmed. All negative people and fixed checks remain. Added unfitted examples test response carryover without an older-history neural amplitude. They do not estimate human bias. We matched all 90 original event tables to the compact inputs. Independent calculations checked all eligible coefficients and one original neural run per modality. The package gives code, compact inputs, 2,016 selected target rows, source pins and terms, all outcomes, figures, and repeat steps. Small cohorts, response selection, model form, filters, response overlap, region placement, and distinct tasks limit scope. The result does not establish absent memory, a shared source, or causality.

EEG · fMRI · auditory oddball · event history · P300 · response overlap · reproducibility

Admitted 0 citing publications

References

10
  1. usesFixed EEG and insula fMRI tests did not confirm positive mean time coefficients after count and response time control sci:sha256:137398c1c84c392181f96ed029b0d88397d1341a47aba15daec85a79379e490e

    We reuse its compact measurements and MIT source and feature code. We add the interval before the last target and a distinct fixed test. Its current-time result does not test this endpoint.

  2. usesThe mean target-gap slope for 300–600 ms Pz EEG voltage was uncertain in 13 participants from ds003061 version 1.1.2 sci:sha256:833373a8c4fa39b4cc81981752e52be62ad6fd8795429cde4502c0ae7ff15ebc

    The inherited EEG object manifest originated here and pins the public source objects.

  3. usesdoi:10.18112/openneuro.ds003061.v1.1.2

    EEG source snapshot.

  4. doi:10.18112/openneuro.ds003061.v1.0.0

    Original attribution requested by the EEG source.

  5. usesdoi:10.1016/j.neuroimage.2013.08.014

    The study supplied auditory fMRI in OpenfMRI ds116 R1.0.0.

  6. usesdoi:10.1523/JNEUROSCI.2649-13.2013

    Companion source-study description.

  7. doi:10.1126/science.959831
  8. doi:10.1017/s0048577201393137
  9. doi:10.1523/JNEUROSCI.2925-08.2008
  10. doi:10.3389/fnhum.2012.00359

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.