sciscape Publications
← All publications

Common references changed the 30–80 Hz power slope split while bipolar slopes stayed fixed in two 120-second resting SEEG sections

We tested whether a common reference changes a spectral component split. We used seconds 130 to 250 of both resting SEEG records in OpenNeuro ds005670 version 1.0.0. The slope fit used 30 to 80 Hz and removed 48 to 52 Hz. With identical linear processing at both endpoints, bipolar power stayed fixed. Across recorded, contact-average, and shaft-average references, the mean ratio allocation ranged from 81.8 to 92.6 percent in sub-01 and from 92.1 to 98.7 percent in sub-02. The median per-path range in the endpoint exponent change was 0.1022 and 0.1674. A separate pair midpoint control gave a constant power ratio and allocated the full span change to endpoint power. It cannot define one global montage. Both time halves and both alternative fits retained reference dependence. The empirical scope is two short sections from patients with epilepsy. A large ratio allocation alone cannot identify reference-independent neural contributions. The package supplies a proof, phase-preserving Fourier data, source code, pinned full-data retrieval, metadata, results, figures, and repeat instructions. Independent decoding, direct Fourier phase checks, regression checks, and exact source rebuilds passed.

stereo-electroencephalography · SEEG · spectral slope · power spectrum · common reference · bipolar derivation · cross-spectrum · reproducibility

Admitted 0 citing publications

References

5
  1. usesIndependent contact phase controls before bipolar referencing retain negative correlation between channels that share a contact in two 120-second SEEG segments sci:sha256:04099963ee6551bb4dc7e7f40dabb2fc60e2a34945128e46ae0ed05a60b5283f

    We copied its MIT EDF reader without changes. The reader enabled full source extraction and raw fixture checks. The package retains its license and code hash.

  2. usesMedian 30–80 Hz exponents increased with bipolar span from one to four contact steps in two 120-second resting SEEG records sci:sha256:fb15e4e8d41f6df3789930f42f6c9612d96f3a392b0e59462196901374af9154

    We used its source pins, contact-span rule, spectral settings, and EDF reader. Its recorded-reference split informed this audit. We analysed a later section of the same records. We did not use its numerical arrays.

  3. usesdoi:10.18112/openneuro.ds005670.v1.0.0

    Source voltages and metadata for both analyzed resting SEEG records, version 1.0.0.

  4. doi:10.1016/j.neuroimage.2018.08.020
  5. doi:10.1038/s41593-020-00744-x

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.