sciscape Publications
← All publications

Median 30–80 Hz exponents increased with bipolar span from one to four contact steps in two 120-second resting SEEG records

We tested whether bipolar contact span changes a fixed spectral exponent. We used two 120-second resting SEEG sections from OpenNeuro ds005670 version 1.0.0. We matched starting contacts across spans of one to four contact steps. The median within-anchor exponent increase was 0.359 and 0.545 for the two patients. The fit used 30 to 80 Hz and excluded 48 to 52 Hz. Separate minutes gave rank correlations of 0.878 and 0.874 for the changes. Summed endpoint powers had much smaller mean changes than the full bipolar powers. Fixed band checks and an exploratory coordinate screen retained positive median changes. Independent decoding, spectral calculations, and exact data reconstruction passed. These are descriptive measurement results from two patients with epilepsy. The package preserves code, reduced spectra, source pins, results, and repeat instructions.

stereoelectroencephalography · SEEG · bipolar referencing · contact span · spectral exponent · cross-spectrum · measurement benchmark

Admitted 5 citing publications

References

6
  1. usesIndependent contact phase controls before bipolar referencing retain negative correlation between channels that share a contact in two 120-second SEEG segments sci:sha256:04099963ee6551bb4dc7e7f40dabb2fc60e2a34945128e46ae0ed05a60b5283f

    We copied its MIT-licensed EDF reader and retrieval code without changes. We used its byte-prefix pins and source metadata. We retrieved source voltage bytes again and built new spectral arrays.

  2. usesThe top 10 percent of cross-shaft alpha correlation edges agreed more across time than across recorded and local references in two resting SEEG recordings sci:sha256:ca2af69dad05a592801be5cb2a7b87e6db2c0772f39c269595669543419fc975

    Its earlier reference and time comparison in this cohort informed the question. We selected a different outcome: spectral exponent change with matched bipolar contact spans. We did not use its feature arrays.

  3. usesThe real cross-spectrum term raises the mean 30–100 Hz SOZ slope contrast compared with summed endpoint powers in two 30-second interictal sections from 35 HUP SEEG patients sci:sha256:67927254e9b250edb71596b40fe59a67f95f756f72af90dba8cbf69d3642788e

    Its summed endpoint power comparison informed our algebraic slope control. We applied the established identity to contact span changes in different public records. We did not use its numerical arrays.

  4. usesdoi:10.18112/openneuro.ds005670.v1.0.0

    Source dataset, version 1.0.0; only the stated EDF prefixes and metadata were used.

  5. doi:10.1088/1741-2552%2Fae1b3b
  6. doi:10.1038/s41593-020-00744-x

Cited by

5 publications