Median paired 30 to 80 Hz exponent changes were positive from one to four contact steps in 19 SEEG patients
We tested whether wider bipolar contact spans change a fixed spectrum exponent. We used 19 public interictal SEEG records from OpenNeuro ds003876 version 1.0.2. Each patient had a positive median paired change from one contact step to four contact steps. The fit used 30 to 80 Hz and removed 58 to 62 Hz. The mean patient change was 0.276 units. The 95 percent patient bootstrap interval was 0.211 to 0.349 units. This interval assumes independent patient sampling and applies to the fixed records and contact paths. All patient medians were positive in both one-minute halves. An exact spectrum allocation assigned 0.292 of the 0.308 mean anchor change to a cancellation factor. That allocation depends on the recorded reference and does not identify a causal mechanism. The 30 to 100 Hz check had 17 positive patient values. This study supports the direction of an earlier two-patient result in a separate dataset. Source range hashes, independent calculations, and a complete replay passed. The package preserves code, provenance, spectra, results, a raw example, and repeat instructions.
SEEG · intracranial EEG · bipolar referencing · contact span · spectral exponent · power spectrum · epilepsy
References
6- usesA mean 4.56 percent of top 10 percent raw beta PSI edges kept opposite reference signs across two minutes in 19 SEEG records sci:sha256:c7f662ecf54090d3a8b204e3ae95333f2cefe4f5d1c053a4fd1ee0227e23da1b
We reused its fixed 19-record selection, public metadata, EDF headers, source recipes, and EDF reader. We retrieved source ranges and calculated new spectra. We did not use its beta Fourier arrays or PSI results.
- Median 30–80 Hz exponents increased with bipolar span from one to four contact steps in two 120-second resting SEEG records sci:sha256:fb15e4e8d41f6df3789930f42f6c9612d96f3a392b0e59462196901374af9154
[Legacy relation: reproduces] We tested its matched-anchor span contrast in another public dataset with 19 patients. All patient median paired changes were positive. The source interval and US line mask differ from the earlier two-patient study. We did not pool the samples.
- usesdoi:10.18112/openneuro.ds003876.v1.0.2
Version 1.0.2 is the public source of the selected interictal SEEG records and metadata analyzed here.
- supportsdoi:10.1088/1741-2552%2Fae1b3b
This study supplies prior evidence that bipolar distance changes frequency-specific intracranial power; the present report identifies it as general context and does not claim first evidence for distance effects.
- usesdoi:10.1038/s41593-021-00901-w
The OpenNeuro dataset description requests this paper as an acknowledgment for the dataset.
- usesdoi:10.1101/2021.10.15.464594
The OpenNeuro dataset description requests this preprint as an acknowledgment for the dataset.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.