Links within shafts had higher agreement than links between shafts in 1–80 Hz SEEG trees from 36 patients
We tested maximum spanning tree link agreement in two interictal files from each of 36 patients in OpenNeuro ds004100 version 1.1.3. At 1–80 Hz, mean retention was 0.828 within electrode shafts and 0.498 between shafts; the mean patient difference was 0.330 (95% patient bootstrap interval 0.290 to 0.375), with a positive difference in all 36 patients. A zero cross-contact covariance control forced a mean 85.6% of tree links through shared contacts, while measured trees had a mean 49.5% shared-contact links. The control fraction does not estimate artifact content. These are short-sample results from patients with epilepsy; clinical sampling, brain state, and montage limit interpretation. The package preserves code, data, hashes, results, and source checks.
SEEG · intracranial EEG · maximum spanning tree · link retention · electrode montage · covariance
References
7- usesIn 36 patients with fixed SEEG contrasts, mean change in estimated canonical correlation spectra was larger between files than between adjacent blocks at 1–80 Hz sci:sha256:1217c177ec55b99e3867daa6135687900230630b32c8a790c700777fcc5adf29
This study uses its 72 covariance archives, sample signals, fixed 36-patient cohort, and source records. It adds tree agreement endpoints.
- usesEdges that share a contact are more common among the strongest 5 percent of 1–80 Hz bipolar SEEG correlations in 36 epilepsy patients sci:sha256:7dc3370736cdefb57323429971522e882b644b700faccfda51b916b3d865f58f
This publication supplies the earlier public range retrieval code and source selection used by the imported extraction records.
- usesZero cross-contact covariance gave mean shaft modularity of 0.903 in 1–80 Hz bipolar absolute correlation models for 36 SEEG patients sci:sha256:f365fd21652627699c341436d59f0f62e54eb790ccef88d7d597a7d9cdf42dd7
This study extends its diagonal contact covariance audit of shaft modularity to maximum spanning tree selection and agreement across files.
- usesTwo bases of the same SEEG contrast space gave different 1–80 Hz correlation participation ratios in 36 patients sci:sha256:901bade82e1972a491fb8b27d87ddf5ae157f439c20fb612d6d24768419473f2
The public source check code and covariance restoration code come through this publication. Licenses and file origins are preserved.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study used the HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3, for all 36 patients. The dataset metadata declares CC0.
- doi:10.1016/j.neulet.2008.09.080
- doi:10.1093/braincomms%2Ffcae165
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesInvertible contrast changes within shafts preserved the Gaussian score between shafts in positive definite 1–80 Hz SEEG covariance from 36 patients
Direct input. It supplies the 72 compact covariance archives, sample signals, source sidecars, range manifest, and public source check code.
- usesRMS canonical correlation gave higher mean shaft tree retention than maximum bipolar correlation in 36 paired 1–80 Hz SEEG cases
This study uses its 72 covariance inputs, fixed contact reader, tree algorithm, and public reconstruction code. It changes the graph nodes from bipolar channels to shafts and compares two shaft link scores.