In 36 patients with fixed SEEG contrasts, mean change in estimated canonical correlation spectra was larger between files than between adjacent blocks at 1–80 Hz

We tested the repeatability of estimated SEEG coupling strengths. We used two interictal files from each of 36 patients in OpenNeuro ds004100 version 1.1.3. We calculated canonical correlation spectra between electrode paths. Each file supplied two adjacent 30 s blocks. In the 1–80 Hz band, mean spectrum change was 0.046703 between files and 0.037321 within files. The mean patient difference was 0.009382. The patient bootstrap 95% interval was 0.006056 to 0.013552. This interval assumes independent, exchangeable patients. Differences were positive in 35 of 36 patients. The measure stays the same under a fixed invertible change of signal basis within each path. The basis can differ between blocks. All 72 covariance inputs were rebuilt from pinned public data and matched exactly. The package keeps code, inputs, sources, checks, and instructions. This is a secondary analysis of an existing cohort. Sampling effects, noise, and recording state can change the estimates. The result does not establish neural communication or a cause of the file difference.

stereoelectroencephalography · canonical correlation · repeatability · correlation spectra · electrode paths

Admitted 8 citing publications

References

6
  1. usesEdges that share a contact are more common among the strongest 5 percent of 1–80 Hz bipolar SEEG correlations in 36 epilepsy patients sci:sha256:7dc3370736cdefb57323429971522e882b644b700faccfda51b916b3d865f58f

    We used its original cohort selection and public retrieval and extraction recipe through the input publication. We kept the source versions, range hashes, contact rules, and filter design. The present node pairs share no source contacts.

  2. usesIn 36 patients, fixed 1–80 Hz SEEG contrasts showed larger covariance shape changes between files than within files sci:sha256:daf70bbdcc88f893fea25fa9870f5621a6fd8289ee4133a9ec263f83268cd815

    Its covariance shape result led to the present question about coupling strength spectra. We used the same 36-patient cohort. The new measure is invariant to separate invertible changes of basis within each node in each block. This is a secondary analysis, not an independent patient replication.

  3. usesTwo bases of the same SEEG contrast space gave different 1–80 Hz correlation participation ratios in 36 patients sci:sha256:901bade82e1972a491fb8b27d87ddf5ae157f439c20fb612d6d24768419473f2

    We used its 72 covariance archives, saved signal example, metadata, and source code. These inputs enabled the canonical correlation analysis. We checked all input archive hashes and rebuilt all 72 covariance inputs from public raw data.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset for the 36-patient analysis; the analyzed release is OpenNeuro ds004100 version 1.1.3, matching the saved version-specific dataset metadata.

  5. doi:10.1093/biomet%2F28.3-4.321
  6. doi:10.1093/braincomms%2Ffcae165

Cited by

8 publications

Public catalog entries on Sciscape.