Haufe patterns repeat better than raw decoder weights across list halves in 18 SEEG patients
In an offline analysis of free-recall (FR1) SEEG data from 18 patients in one session, we compared decoder maps fitted to the first and second halves of word lists. The data were 704–1384 log-power features per patient at eight frequencies. For shrinkage LDA, the Haufe pattern repeated better than the raw weight map: median Pearson r was 0.248 versus 0.033, and the Fisher-z difference favored the pattern in 17/18 patients (mean D = 0.224; exact one-sided sign-flip p = 7.6e-6). The result also held for 80+140 Hz, L2 logistic regression, and an odd/even list split. The pattern repeated slightly better than a Welch t map (p = 0.013). However, top-10% feature overlap was low (median Jaccard 0.065 for patterns), and weight stability had a stronger association with transfer AUC than pattern stability for LDA (Spearman rho 0.69 vs 0.34). Both maps exceeded a 200-draw label-shuffle null; the pattern null was about three times wider. A post-hoc comparison scaled by each map’s own null still favored the pattern, but with a smaller effect (15/18 patients, p = 0.0025). The secondary tests were not corrected for multiple comparisons. The study covers one task, one session, and 18 patients; it is offline, and its maps do not identify a reliable set of top contacts from half a session.
stereo-EEG · free recall · word recall · Haufe pattern · decoder weights · shrinkage LDA · feature stability · brain-computer interface
References
5- usesIn 18 SEEG patients, theta plus high-frequency bands nearly matched the 8-band recall decoder, while high-frequency activity alone lost 0.029 AUC sci:sha256:2c12abf1d98076d8501092991bab5c9355447b7a2c6f34d69a90e61c700e53f1
The analysis uses the archived per-word FR1 SEEG features (ds004789, session 0) of this publication as input. The MD5 checksums of all 19 files match.
- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
The analysis uses the patient inclusion rule, the label-free session z-score and the L2 logistic decoder (C = 7.2e-4, balanced classes) of this publication.
- supportsHaufe activation patterns repeated better than LDA weights across early and late SEEG key-press trials in 6 of 8 subjects sci:sha256:c521e7b6c2ddbb133f77a25a3c744adf38dfa41880163d07cb51da8009c992fa
On a different task and data set (FR1 word recall, ds004789, 18 patients, 704-1384 features), the Haufe pattern again repeated between two blocks of one session better than the raw LDA weights (17/18 patients, exact sign-flip p = 7.6e-6). A post-hoc check that scaled each r by its own label-shuffle null also showed the effect (15/18, p = 0.0025).
- usesHaufe activation patterns repeated better than LDA weights across early and late SEEG key-press trials in 6 of 8 subjects sci:sha256:c521e7b6c2ddbb133f77a25a3c744adf38dfa41880163d07cb51da8009c992fa
The analysis uses the map-stability method and the unchanged numpy shrinkage-LDA code (lda_np.py) of this publication.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The analyzed archived per-word FR1 SEEG features come from OpenNeuro ds004789 v3.1.0, session 0.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsHaufe activation patterns repeated better than raw LDA weights across trial blocks in one-session SEEG data from 15 patients
Same direction (pattern repeats better than raw weights) in a movement decoder; that work used ds004789 memory decoding.