Haufe activation patterns repeated better than raw LDA weights across trial blocks in one-session SEEG data from 15 patients
In an independent SEEG dataset and task, Haufe activation patterns from the first 60% of trials repeated on the last 40% better than raw shrinkage-LDA weights. We analysed archived 70–150 Hz high-gamma features from 15 patients in OpenNeuro ds006253, comparing mouse movement with pre-stimulus rest within one offline session. Median map correlation across channels was 0.72 for patterns and 0.53 for weights; the mean Fisher-z difference was +0.335, positive in 14 of 15 patients (exact one-sided sign-flip p = 6.1×10⁻⁵), meeting the pre-registered replication criterion. Pattern stability did not exceed that of a univariate t map (mean difference 0.0001, p = 1.0). Top-10% channel overlap favored patterns by 0.107 Jaccard units (p = 0.021), while median pattern overlap remained 0.30. Map stability was associated with transfer AUC (Spearman rho 0.80 for weights and 0.69 for patterns). Combined descriptively with the earlier ds004473 result, D was positive in 20 of 23 patients. These findings support using activation patterns or univariate t maps rather than raw LDA weights for channel planning from clinical SEEG. The analysis was offline and covered one session per patient; movement and rest features came from different task phases, so some map differences may reflect task state. Only 70–150 Hz activity was analysed, and contact anatomy was not compared.
SEEG · brain-computer interface · linear discriminant analysis · Haufe activation pattern · decoder interpretability · high-gamma activity · movement decoding · map stability · OpenNeuro ds006253
References
4- supportsHaufe patterns repeat better than raw decoder weights across list halves in 18 SEEG patients sci:sha256:0302d953c8a31a0f3fe8b355a52eb18f0cb1f30c716902a73fedd3b8703dd298
Same direction (pattern repeats better than raw weights) in a movement decoder; that work used ds004789 memory decoding.
- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
Archived per-trial 70-150 Hz HGA MOVE/REST features of 15 ds006253 patients, copied without change; LDA and AUC code copied.
- Haufe activation patterns repeated better than LDA weights across early and late SEEG key-press trials in 6 of 8 subjects sci:sha256:c521e7b6c2ddbb133f77a25a3c744adf38dfa41880163d07cb51da8009c992fa
[Legacy relation: reproduces] Same map-repeat test (Haufe pattern vs raw LDA weight) in an independent dataset, task and center (ds006253, 15 patients); the result replicated (14/15, p = 6.1e-5).
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analysed archived per-trial features are derived from the author 70–150 Hz HGA derivative of OpenNeuro ds006253; saved provenance and metadata identify release 1.0.3.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.