sciscape Publications
← All publications

Absolute cosine reduced mean four-site accuracy in eight STReEF SEEG patients after recorded contact order reversal

We tested whether absolute cosine improves site identification after recorded stimulation contact order reversal. We used public STReEF SEEG data from eight patients with epilepsy. Each patient supplied four sites, four recording pairs, and five fit pulses per site. Testing used 160 separate pulses in total. The feature window was 20 to 100 ms. Signed cosine gave 100 correct decisions; absolute cosine gave 91. Mean accuracy decreased from 62.5% to 56.9%. The exact paired patient test gave p = 0.125. Absolute scoring gained seven correct answers and lost sixteen. Artificial global sign changes left all absolute decisions fixed. Recorded order reversal did not produce a uniform global response sign change. Only 40 test pulses occurred after all fitting pulses for their patient. The sample and earlier signed results were known. The result does not establish a population effect or live BCI performance. We preserve three figures, code, fitted readers, pulse decisions, source hashes, and reproduction instructions. Fresh retrieval matched all 320 raw epochs. A new Python environment repeated the analysis and matched the preserved inputs and results.

stereoelectroencephalography · electrical brain stimulation · cosine similarity · site classification · brain-computer interfaces · signal processing

Admitted 0 citing publications

References

6
  1. usesFull covariance gave no mean gain in offline four-site accuracy after stimulation contact order reversal with four SEEG pairs and five fit pulses per site in eight patients sci:sha256:95cbee7f35c613bb0a1e9dcec2a9050e739bf40b912513d180f112c1f73e51a5

    Reused the fixed four-site sample, DCT feature recipe, source retrieval code, metadata checks, and raw-range hashes. Fresh reconstruction matched every input array.

  2. usesGlobal amplitude removal lowered mean site accuracy after recorded contact order reversal in eight STReEF patients with four SEEG pairs sci:sha256:84285597246fb5fb9c594f376f9def4dfde8ac5b145d2ad68c66a8f5b3927cf3

    Reused global signed cosine as the matched comparator. The same fit means, residual variance scales, and pair ranking isolated the effect of absolute scoring. All patient correct counts matched.

  3. usesAbsolute pair scores kept SEEG site decisions fixed under simulated output sign reversals in five sessions sci:sha256:8a26582c314b8be03ef05d9206ae910fa50daac8c1ccee11c5df2d7794d6821e

    Used its simulated recording-sign comparison to motivate a test of recorded stimulation contact order transfer. This study uses another dataset and complete-vector cosine.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analyzed public data are STReEF, OpenNeuro ds005448 version 1.0.0; source metadata identifies this exact release and declares CC0.

  5. doi:10.1007/s12021-022-09567-6
  6. doi:10.1016/j.ynirp.2025.100274

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.