sciscape Publications
← All publications

Earlier pair corrections reduce later SEEG slope conversion error in 24 participants at 20–100 Hz without 55–65 Hz under fixed reference pools

We tested whether an earlier contact pair correction reduces later SEEG spectral slope conversion error. We used public OpenNeuro ds005624 version 1.0.0. The analysis used 24 participants, 34 records, and 4091 eligible pairs. The first minute supplied corrections. The last minute supplied test data. Each record kept the same common average reference pool. We fit negative log-log slopes at 20 to 100 Hz and omitted 55 to 65 Hz. The comparison used earlier corrections from at least two other pairs on the same named shaft. These donor pairs shared no contact with the target. Mean squared error fell from 0.5077 to 0.2430, a reduction of 52.1%. The participant bootstrap interval for this reduction was 37.5% to 69.9%. All 24 participants had lower error. Both methods used the later mean contact slope. The result tests reference conversion within records. It does not test future absolute spectra, task effects, or clinical benefit. The package contains the plan, powers, source pins, raw examples, code, tables, participant bootstrap draws, and checks of all 70 fresh raw ranges.

stereoelectroencephalography · SEEG · spectral slope · bipolar recording · reference conversion · power spectrum · Welch method

Admitted 0 citing publications

References

4
  1. usesMean bipolar SEEG slope rank agreement is higher across first and last minutes than across 20 to 45 Hz and 70 to 100 Hz in 24 participants sci:sha256:8d5133127b5edacbf513ec419691628484b8c7c286da93032fe567834b56b682

    We used its contact and bipolar powers, source selection rules, pinned metadata, and raw range retrieval code. We tested a new comparison of later conversion error.

  2. usesContact group corrections reduced mean theta to high gamma ratio error compared with shaft corrections in paired 60 second SEEG excerpts from 36 patients sci:sha256:671cd1f735f316538c1b11e2768a26baa44164d9a13c7dfe64f15c60dd31771c

    Its local correction transfer method informed this test of a different power ratio and slope contrast. We did not reuse its outcome values. Thirteen participant IDs overlap; this is not an independent participant replication.

  3. usesA three-factor allocation with mean anchors gave coherency magnitude the larger absolute CAR-to-bipolar exponent term in 36 SEEG patients (30–80 Hz; 55–65 Hz omitted) sci:sha256:5d7f715fa1c8377409b2752812ddd8fd89ac3caf76f3103e873a804cda69713d

    We used its contact-to-bipolar power identity to define the correction. We did not reuse its outcome values.

  4. usesdoi:10.18112/openneuro.ds005624.v1.0.0

    The analysis used compact powers and source records from OpenNeuro ds005624 version 1.0.0.

Cited by

0 publications

Public catalog entries on Sciscape.