sciscape Publications
← All publications

Contact group corrections reduced mean theta to high gamma ratio error compared with shaft corrections in paired 60 second SEEG excerpts from 36 patients

We tested a correction for each contact group in public interictal SEEG data. We used paired 60 second excerpts from 36 patients in OpenNeuro ds004100 version 1.1.3. There were 2703 four contact groups on 455 inferred shafts. Corrections used file 01 only. Predictions used narrow ratios in file 02 and were scored against measured wide ratios in file 02. Mean absolute theta to high gamma ratio error was 1.279 dB for group corrections and 2.248 dB for shaft corrections. The mean reduction was 0.969 dB. The 95 percent patient bootstrap interval was 0.793 to 1.145 dB. A population interpretation requires independent and exchangeable patient effects. There were 32 positive effects, one negative effect, and three zero effects. All seven planned checks had positive mean reductions. A secondary spectral decomposition assigned 86.6 percent of the mean span difference to cross terms. Shared contacts and noise can create these terms. They do not identify neural coupling. All 36 compact patient files matched a fresh extraction from 72 pinned public EDF prefixes. A separate analysis reproduced all numerical outputs. This test concerns recorded montage ratios in the same patients. It does not establish transfer to new patients or long time gaps. The package preserves source code, compact spectra, raw retrieval locks, metadata, all scores, bootstrap draws, validation, and reproduction instructions.

stereoelectroencephalography · bipolar recordings · spectral power ratio · theta · high gamma · contact group correction · signal processing

Admitted 3 citing publications

References

4
  1. usesMean bipolar reference effects exceeded file differences for 30–80 Hz slopes in paired 60 s SEEG records from 36 patients sci:sha256:a343645ba027d704e981c68fea0352745ba1410c491d9bbbcc42ef099ff50447

    The fixed retained contact order and EDF retrieval methods came from this study through the span study. We preserved the imported code license and retained the cohort without new selection.

  2. usesThree interval bipolar spans increased theta to high gamma ratios in paired 60 second SEEG excerpts from 36 patients sci:sha256:e716a2c7f84cd2da498c72ee13ea049873f161c6f2859db82eb36ebef2f91680

    We used all 36 patient spectra, fixed contact groups, source metadata, raw source locks, and unchanged extraction code. These inputs supported the file transfer test and spectral decomposition.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis used the HUP iEEG Epilepsy Dataset, version 1.1.3, as identified in the source records.

  4. doi:10.1088/1741-2552%2Fae1b3b

Cited by

3 publications