Four pulses captured a median 90% of the above-chance AUC of a 10-pulse SEEG N1 map in 8 patients

We evaluated how many single-pulse electrical stimulation (SPES) pulses are needed to reproduce expert N1 labels in SEEG cortico-cortical evoked potential maps. In 8 patients from OpenNeuro ds005448 v1.0.0, we analyzed 157 stimulated pairs and 13,794 pair-contact tests. A negative-peak z-score from the average of 1–10 pulses was compared with expert labels using ROC AUC; group tests were exact two-sided Wilcoxon tests over patients. Median AUC was 0.711 for 1 pulse, 0.773 for 4 pulses, and 0.808 for 10. Four pulses (range 2–7) reached a median 90% of the above-chance AUC of 10 pulses; 7 pulses (range 3–9) reached 95%. Each pulse count below 10 had lower AUC than 10 pulses, with 8/8 patients lower for counts up to 6. Pulse polarity and order did not change detection (median AUC differences within ±0.01; p > 0.4). For polarity-balanced halves, split-half waveform map correlation was 0.719 with 2 pulses per half and 0.820 with 4, below the Spearman–Brown prediction of 0.836 in 8/8 patients (p = 0.0078). Single-pulse N1 amplitude did not decrease within five-pulse polarity blocks (p = 0.84); the first block was larger in 7/8 patients, but polarity and block order were confounded. Interpretation is limited by expert labels based on the average of all pulses, which gives k = 10 agreement a positive bias; the detector scores negative peaks although only 21–65% of expert N1 amplitudes were negative. The study used one center, one current per pair, and 1–2 mA monophasic pulses. These results describe agreement with the full-protocol expert map, not recovery of true connectivity.

SEEG · cortico-cortical evoked potentials · single-pulse electrical stimulation · N1 · effective connectivity · pulse count · map reliability · OpenNeuro ds005448

Admitted 2 citing publications

References

3
  1. usesPre-stimulus band power did not predict single-trial N1 amplitude in 8 SEEG patients sci:sha256:4f0265f951d04b7e57cbc7c33bc06c514d421406a8cd4b9c2ed362c6976ebc7b

    We used its fetch.py and s3ls.py (byte-range epoch reads of ds005448 SPESclin runs and the expert N1sChecked labels). We changed the epoch window to -0.15..+0.10 s and the pair count to 20 per patient.

  2. supportsIn one SEEG patient, five-pulse CCEP maps correlated at 0.74 and gained less reliability than independent-noise averaging predicts sci:sha256:63bb98b935cd8ac712d5357a0fe4e173b7ab170d60406948ac869e9b8833d333

    In 8 ds005448 patients, the split-half CCEP waveform map correlation from 2 to 4 pulses per half was below the Spearman-Brown prediction in 8/8 patients (median -0.016, p = 0.0078), and from 1 to 3 pulses the shortfall was -0.068. This agrees with the one-patient result that map reliability increases more slowly than independent-noise averaging predicts, with a different dataset, center and map measure.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    This versioned OpenNeuro dataset supplies the SPESclin recordings and expert N1 labels analyzed here.