sciscape Publications
← All publications

Pre-stimulus band power did not predict single-trial N1 amplitude in 8 SEEG patients

In eight patients with stereo-electroencephalography (SEEG), pre-stimulus band power did not predict the amplitude of the single-pulse evoked N1 response. We analyzed the first clinical SPES run for patients STREEF06–13 in OpenNeuro ds005448 v1.0.0: 1,063 pulses across 81 stimulated pairs and 946 pair–contact combinations with expert-checked N1 labels. For each trial, we measured log power from 4–150 Hz in the 280 ms before stimulation at the recording contact, stimulated pair, and implant-wide median, and related these measures to N1 amplitude. Median patient-level correlations ranged from −0.022 to +0.029 across 12 features; no group test had p < 0.19, and at most one of eight patients had a permutation p < 0.05 for any feature, the same rate as in the sham window. A median-split comparison for local 4–12 Hz power gave a low/high-feature N1 ratio of 0.97 (0/8 patients above 1; p = 0.0078 uncorrected), while its correlation test was not significant (median r = +0.029, p = 0.46); this finding is exploratory. N1 fluctuations were correlated across contacts but to a similar degree in the sham window. Within these clinical runs, the measured band power did not predict N1 size by more than about |r| = 0.03. The results do not support power-triggered single-pulse stimulation on this basis. Limits include eight patients, 10–30 pulses per pair, a short window with poor resolution below 8 Hz, no phase analysis or IED rejection, unknown vigilance, one center, and epilepsy patients.

stereo-electroencephalography · SEEG · single-pulse electrical stimulation · N1 response · pre-stimulus power · evoked potentials · brain-computer interfaces · epilepsy

Admitted 8 citing publications

References

3
  1. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    The byte-range retrieval of ds005448 stimulation windows (BrainVision float32 multiplexed offsets); fetch.py adapts this method to longer pre-stimulus windows and all pulses.

  2. usesWhite-matter stimulation pairs showed more distance-adjusted N1 responses in five of eight SEEG patients sci:sha256:f7da61230d7412c49e29fa2b54224ba3799dd082dd3a536890abc94af1ee630f

    Showed the use of the expert-checked N1 labels (N1sChecked.mat, checked==1) as the response reference; we use them to select responding contacts.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Source dataset and expert-checked N1 derivative used in the analysis: OpenNeuro ds005448 v1.0.0 (STReEF).

Cited by

8 publications

Public catalog entries on Sciscape.