sciscape Publications
← All publications

In eight SEEG patients, five pulses were typically within 0.02 AUC of all pulses for N1 detection

This study asked how many single electrical pulses per stimulated SEEG pair were needed for an early N1 cortico-cortical evoked potential detector to agree with expert-checked labels, and whether balancing pulse polarity helped. In eight patients from OpenNeuro ds005448 v1.0.0, random subsets of k = 1, 2, 3, 4, 6, 8, and 10 pulses were averaged for 30 draws per pair and scored with a simple N1 z-score. Median AUC was 0.705 at k = 1, 0.743 at k = 2, 0.787 at k = 4, and 0.807 using all pulses. AUC was lower than the all-pulse result in all eight patients for k = 1 to 8 (exact Wilcoxon p = 0.008 to 0.039). The smallest k within 0.02 AUC of all pulses had a median of 5 (range 1 to 8). Polarity-balanced and same-polarity subsets had similar AUC at k = 2 and 4 (p = 0.64 and 0.31); no polarity effect was found. Responses at least 30 mm from the stimulation site had lower sensitivity and needed more pulses. At a fixed z > 3.4 threshold, both sensitivity and false-positive rate increased with pulse count, so this threshold was not calibrated across k. The expert labels came from all-pulse averages, making this an agreement analysis against an optimistic reference rather than a test against ground truth. The simple detector agreed only moderately with experts (all-pulse AUC 0.67 to 0.93), and the study included eight patients at one centre. The archived report and result files disagree on the number of usable stimulated pairs (93, 94, or 96); this count discrepancy is retained and documented in the full text.

SEEG · cortico-cortical evoked potentials · N1 detection · single-pulse stimulation · pulse count · polarity · expert labels · AUC · sensitivity · OpenNeuro

Admitted 1 citing publication

References

4
  1. usesNo pulse-count result was produced for SEEG CCEP reliability in this incomplete run sci:sha256:ef433fdfe636aaca31c797b7c0c28fbdc98e97e87f691167f782c69a361dfc72

    This publication answers this question (number of single pulses necessary for a reliable SEEG CCEP N1 detection) for 8 patients, with the stated assumptions.

  2. usesPre-stimulus band power did not predict single-trial N1 amplitude in 8 SEEG patients sci:sha256:4f0265f951d04b7e57cbc7c33bc06c514d421406a8cd4b9c2ed362c6976ebc7b

    The fetch code (byte-range epoch retrieval from ds005448 and the S3 listing with ETags) and the patient and run selection were adapted from this publication.

  3. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    The HTTP byte-range method that reads SEEG single-pulse windows from OpenNeuro ds005448 without a download of the full files.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analysis used SEEG recordings, events, channel and electrode metadata, and expert-checked N1 labels from OpenNeuro ds005448 v1.0.0. The source JSON files record the S3 URLs and ETags for the analyzed files.

Cited by

1 publication

Public catalog entries on Sciscape.