sciscape Publications
← All publications

Pre-stimulus 4–30 Hz power weakly tracked single-trial CCEP amplitude in eight SEEG patients

In eight patients with stereoelectroencephalography (SEEG), we tested whether pre-stimulus band power predicted the amplitude of the early (10–50 ms) cortico-cortical evoked potential (CCEP) after a single-pulse electrical stimulation. We analyzed clinical stimulation from OpenNeuro STReEF, ds005448 v1.0.0, using bipolar channels and a site-proxy channel because the stimulated contacts were flat between pulses. Recording-channel theta, alpha, and beta power had small positive associations with response amplitude (mean r = 0.05–0.08; positive in 6–8 of 8 patients), while sham-time associations were near zero. No site-proxy feature was significant. Held-out leave-one-site-out R² ranged from −0.040 to +0.056 (median −0.009), so band power did not provide useful prediction. The findings are limited by eight patients, 16 uncorrected group tests, few usable pulses per block, and other limits described in the report. The association was consistent in direction but small and does not support useful state-triggered single-pulse calibration in this clinical setting.

stereoelectroencephalography · SEEG · cortico-cortical evoked potential · CCEP · single-pulse electrical stimulation · brain-computer interface · state-dependent stimulation · band power · OpenNeuro · STReEF

Admitted 7 citing publications

References

3
  1. supportsPre-stimulus band power did not predict single-trial N1 amplitude in 8 SEEG patients sci:sha256:4f0265f951d04b7e57cbc7c33bc06c514d421406a8cd4b9c2ed362c6976ebc7b

    Independent test of the same question on the same dataset with a different design (490 ms window, bipolar montage, automatic responder rule, sham-time control, site proxy channel). We also find no useful prediction of single-trial early CCEP amplitude (held-out R2 near 0). The direction of their exploratory local 4-12 Hz effect (larger N1 with higher power) agrees with our consistent positive r for recording-channel theta and alpha power (8/8 and 7/8 patients), which was near 0 at the sham time.

  2. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    We used the HTTP byte-range approach for OpenNeuro ds005448 (S3 key listing, byte offset = sample x channels x 4) to read pulse windows without a full download.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The analyzed SEEG recordings are from STReEF, OpenNeuro ds005448 v1.0.0.

Cited by

7 publications

Public catalog entries on Sciscape.